Search results
Results From The WOW.Com Content Network
Positive end-expiratory pressure (PEEP) is the pressure in the lungs (alveolar pressure) above atmospheric pressure (the pressure outside of the body) that exists at the end of expiration. [1] The two types of PEEP are extrinsic PEEP (PEEP applied by a ventilator) and intrinsic PEEP (PEEP caused by an incomplete exhalation).
PEEP: positive end-expiratory pressure: PEF: peak expiratory flow: PEFR: peak expiratory flow rate: PEG: percutaneous endoscopic gastrostomy: PEM: protein/energy malnutrition (aka Kwashiorkor) pen: penicillin (Best practice is to avoid drug name abbreviations) PEP: Post-exposure prophylaxis [4] PERM: Progressive Encephalomyelitis with Rigidity ...
Abbrev. [1]Meaning [1] Latin (or Neo-Latin) origin [1]; a.c. before meals: a.d., ad, AD right ear auris dextra a.m., am, AM morning: ante meridiem: nocte every night ...
Pronunciation follows convention outside the medical field, in which acronyms are generally pronounced as if they were a word (JAMA, SIDS), initialisms are generally pronounced as individual letters (DNA, SSRI), and abbreviations generally use the expansion (soln. = "solution", sup. = "superior").
The therapy is an alternative to positive end-expiratory pressure (PEEP). Both modalities stent open the alveoli in the lungs and thus recruit more of the lung surface area for ventilation. However, while PEEP refers to devices that impose positive pressure only at the end of the exhalation , CPAP devices apply continuous positive airway ...
An adjustable pressure-limiting valve (commonly abbreviated to APL valve, and also referred to as an expiratory valve, relief valve or spill valve) is a type of flow control valve used in anaesthesiology as part of a breathing system. It allows excess fresh gas flow and exhaled gases to leave the system while preventing ambient air from entering.
Bag valve mask. Part 1 is the flexible mask to seal over the patients face, part 2 has a filter and valve to prevent backflow into the bag (prevents patient deprivation and bag contamination) and part 3 is the soft bag element which is squeezed to expel air to the patient
The rates used vary widely depending upon patient size, age, and disease process. In HFOV the pressure oscillates around the constant distending pressure (equivalent to mean airway pressure [MAP]) which in effect is the same as positive end-expiratory pressure (PEEP). Thus gas is pushed into the lung during inspiration, and then pulled out ...