The FT-IR spectra were recorded using a Nicolet 170SX or a JASCO FT/IR-410 spectrometer. For spectra recorded in the Nicolet spectrometer, the data were stored at intervals of 0.5 cm −1 in the 4,000 – 2,000 cm −1 region and of 0.25 cm −1 in the 2,000 – 400 cm −1 region and the spectral resolution was 0.25 cm −1.
Fourier transform infrared spectroscopy (FTIR) [1] is a technique used to obtain an infrared spectrum of absorption or emission of a solid, liquid, or gas. An FTIR spectrometer simultaneously collects high-resolution spectral data over a wide spectral range.
The sample will absorb some of the light, causing the spectra to be different. The ratio of the "sample spectrum" to the "background spectrum" is directly related to the sample's absorption spectrum. Accordingly, the technique of "Fourier-transform spectroscopy" can be used both for measuring emission spectra (for example, the emission spectrum ...
There are two main approaches to two-dimensional spectroscopy, the Fourier-transform method, in which the data is collected in the time-domain and then Fourier-transformed to obtain a frequency-frequency 2D correlation spectrum, and the frequency domain approach in which all the data is collected directly in the frequency domain.
The SPC file format is a file format in which all kinds of spectroscopic data, including among others infrared spectra, Raman spectra and UV/VIS spectra. The format can be regarded as a database with records of variable length and each record stores a different kind of data (instrumental information, information on one spectrum of a dataset ...
Reflection-absorption FTIR: Sample is usually prepared as a thick block and is polished into a smooth surface. [4] As the IR beam strikes the sample surface, some of the energy is absorbed by the top layer (<10 μm) of the bulk sample. The altered incident beam is then reflected and carry the composition information of the targeted surface area.
The spectra are plotted in units of log inverse reflectance (log 1/R) versus wavenumber. Alternative plots of Kubelka-Munk units can be used, which relate reflectance to concentration using a scaling factor. A reflectance standard is needed in order to quantify the reflectance of the sample because it cannot be determined directly. [2] [3]
An infrared spectroscopy correlation table (or table of infrared absorption frequencies) is a list of absorption peaks and frequencies, typically reported in wavenumber, for common types of molecular bonds and functional groups.