In telecommunications, insertion loss is the loss of signal power resulting from the insertion of a device in a transmission line or optical fiber and is usually expressed in decibels (dB). If the power transmitted to the load before insertion is P T and the power received by the load after insertion is P R, then the insertion loss in decibels ...
The insertion loss is not such a problem for an unequal split of power: for instance -40 dB at port 3 has an insertion loss less than 0.2 dB at port 2. Isolation can be improved at the expense of insertion loss at both output ports by replacing the output resistors with T pads. The isolation improvement is greater than the insertion loss added ...
The extra loss may be due to intrinsic loss in the DUT and/or mismatch. In case of extra loss the insertion loss is defined to be positive. The negative of insertion loss expressed in decibels is defined as insertion gain and is equal to the scalar logarithmic gain (see: definition above).
A match is good if the return loss is high. A high return loss is desirable and results in a lower insertion loss. From a certain perspective 'Return Loss' is a misnomer. The usual function of a transmission line is to convey power from a source to a load with minimal loss. If a transmission line is correctly matched to a load, the reflected ...
Path loss is a major component in the analysis and design of the link budget of a telecommunication system. This term is commonly used in wireless communications and signal propagation. Path loss may be due to many effects, such as free-space loss, refraction, diffraction, reflection, aperture-medium coupling loss, and absorption. Path loss is ...
Performance of optical fiber connectors can be quantified by insertion loss and return loss. Measurements of these parameters are now defined in IEC standard 61753-1. The standard gives five grades for insertion loss from A (best) to D (worst), and M for multimode. The other parameter is return loss, with grades from 1 (best) to 5 (worst).
The path loss will be in terms of dB per unit distance. This means that there is always a crossover distance beyond which the loss in a guided medium will exceed that of a line-of-sight path of the same length. Long distance fiber-optic communication became practical only with the development of ultra-transparent glass fibers.
Coupling loss is usually expressed in the same units—such as watts or decibels—as in the originating circuit element or medium. [1] Coupling loss in fiber optics refers to the power loss that occurs when coupling light from one optical device or medium to another. (See also Optical return loss.) Coupling losses can result from a number of ...