When.com Web Search

  1. Ad

    related to: emerson dp level transmitter calculation chart 1 0 2 al urd wire

Search results

  1. Results From The WOW.Com Content Network
  2. Rosemount Inc. - Wikipedia

    en.wikipedia.org/wiki/Rosemount_Inc.

    Rosemount Inc. is a subsidiary of Emerson Electric Company.Its headquarters is located in Shakopee, Minnesota, where they manufacture measurement instrumentation such as pressure, temperature, level, DP flow, and wireless, as well as analytical and detection instrumentation for gas analysis, liquid analysis, combustion measurement and flame and gas detection.

  3. Level sensor - Wikipedia

    en.wikipedia.org/wiki/Level_sensor

    These detect levels of very fine powders (bulk density: 0.02–0.2 g/cm 3), fine powders (bulk density: 0.20.5 g/cm 3), and granular solids (bulk density: 0.5 g/cm 3 or greater). With proper selection of vibration frequency and suitable sensitivity adjustments, they can also sense the level of highly fluidized powders and electrostatic ...

  4. DP cell - Wikipedia

    en.wikipedia.org/wiki/Dp_cell

    The DP-cell will indicate the relative difference between the pressure of the vessel (container) and the atmospheric pressure. This signal is often wired to an indicator that reads out locally, or remotely in a control room, and/or as a control (or feedback) signal to a valve, pump, or other control element to maintain a set pressure, or limit ...

  5. Highway Addressable Remote Transducer Protocol - Wikipedia

    en.wikipedia.org/wiki/Highway_Addressable_Remote...

    The HART Communication Protocol (Highway Addressable Remote Transducer) is a hybrid analog+digital industrial automation open protocol. Its most notable advantage is that it can communicate over legacy 4–20 mA analog instrumentation current loops, sharing the pair of wires used by the analog-only host systems.

  6. EPNdB - Wikipedia

    en.wikipedia.org/wiki/EPNdB

    It is defined, with computational instructions, in Annex 16 [1] [2] of the Convention on International Civil Aviation and in Part 36 of the US Federal Aviation Regulations. [3] The scaling is such that the EPNdB rating represents the integrated noisiness over a ten-second period; EPNdB of 100 dB means that the event has the same integrated ...

  7. Low-voltage differential signaling - Wikipedia

    en.wikipedia.org/wiki/Low-voltage_differential...

    In a typical implementation, the transmitter injects a constant current of 3.5 mA into the wires, with the direction of current determining the digital logic level. The current passes through a termination resistor of about 100 to 120 ohms (matched to the cable's characteristic impedance to reduce reflections) at the receiving end, and then ...

  8. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    With C v = 1.0 and 200 psia inlet pressure, the flow is 100 standard cubic feet per minute (scfm). The flow is proportional to the absolute inlet pressure, so the flow in scfm would equal the C v flow coefficient if the inlet pressure were reduced to 2 psia and the outlet were connected to a vacuum with less than 1 psi absolute pressure (1.0 ...

  9. Current loop - Wikipedia

    en.wikipedia.org/wiki/Current_loop

    Another loop may contain two passive chart recorders, a passive pressure transmitter, and a 24 V battery (the battery is the active device). Note that a 4-wire instrument has a power-supply input separate from the current loop. Panel mount displays and chart recorders are commonly termed "indicator devices" or "process monitors".