Ads
related to: vertical air intake louvers reviews problems and solutions video
Search results
Results From The WOW.Com Content Network
If they are located closely together, supply air may mix with stale air, decreasing the efficiency of the HVAC system, and creating air quality problems. System imbalances occur when components of the HVAC system are improperly adjusted or installed and can create pressure differences (too much-circulating air creating a draft or too little ...
It applies to a fan or other air moving device when air is used as the test gas with the following exceptions: (a) air circulating fans (ceiling fans, desk fans); (b) positive pressure ventilators; (c) compressors with inter-stage cooling; (d) positive displacement machines; (e) test procedures to be used for design, production, or field testing.
Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.
Displacement ventilation is best suited for taller spaces (higher than 3 meters [10 feet]). [2] Standard mixing ventilation may be better suited for smaller spaces where air quality is not as great a concern, such as single-occupant offices, and where the room height is not tall (e.g., lower than 2.3 meters [7.5 feet]).
An automatic louver or damper that controls the fresh air flow into an air handler and modulates to the most energy efficient setting. outside air temperature A measure of the air temperature outside a building.
Passive ventilation is the process of supplying air to and removing air from an indoor space without using mechanical systems. It refers to the flow of external air to an indoor space as a result of pressure differences arising from natural forces.
A louver is provided in an area where mechanical equipment located inside the building requires ventilation or fresh air to operate. They can also serve as a means of allowing outside air to filter into the building to take advantage of favorable climatic conditions and minimize the usage of energy-consuming HVAC systems. Curtain wall systems ...
Vertical section through a commercial building using HVAC plenum instead of airspace plenum. When both the supply and return ducts are constructed in this manner, it is possible to insulate the ducts and the dropped ceiling so that the upper airspace is not heated or cooled, increasing energy efficiency.