  2. Modbus - Wikipedia

    en.wikipedia.org/wiki/Modbus

    Unit identifier is used with Modbus TCP devices that are composites of several Modbus devices, e.g. Modbus TCP to Modbus RTU gateways. In such a case, the unit identifier is the Server Address of the device behind the gateway. A MODBUS TCP/IP ADU/Modbus TCP frame format then will be: [31] [30]

  3. IEC 60870-5 - Wikipedia

    en.wikipedia.org/wiki/IEC_60870-5

    The standard uses an open TCP/IP interface to network to have connectivity to the LAN (local area network) and routers with different facility (ISDN, X.25, Frame Relay etc.) can be used to connect to the wide area network (WAN). Application layer of IEC 104 is preserved same as that of IEC 101 with some of the data types and facilities not used.

  4. List of TCP and UDP port numbers - Wikipedia

    en.wikipedia.org/wiki/List_of_TCP_and_UDP_port...

    This is a list of TCP and UDP port numbers used by protocols for operation of network applications. The Transmission Control Protocol (TCP) and the User Datagram Protocol (UDP) only need one port for bidirectional traffic. TCP usually uses port numbers that match the services of the corresponding UDP implementations, if they exist, and vice versa.

  5. IEC 61850 - Wikipedia

    en.wikipedia.org/wiki/IEC_61850

    IEC 61850 is an international standard defining communication protocols for intelligent electronic devices at electrical substations.It is a part of the International Electrotechnical Commission's (IEC) Technical Committee 57 reference architecture for electric power systems. [1]

  6. Fieldbus - Wikipedia

    en.wikipedia.org/wiki/Fieldbus

    Here we find the solutions Ethernet/IP, three versions of PROFINET IO - the classes A, B, and C - and the solutions of P-NET, [28] Vnet/IP [29] TCnet, [30] EtherCAT, Ethernet POWERLINK, Ethernet for Plant Automation (EPA), and also the MODBUS with a new Real-Time Publish-Subscribe MODBUS-RTPS and the legacy profile MODBUS-TCP.

  7. Industrial Ethernet - Wikipedia

    en.wikipedia.org/wiki/Industrial_Ethernet

    Protocols for industrial Ethernet include EtherCAT, EtherNet/IP, PROFINET, POWERLINK, SERCOS III, CC-Link IE, and Modbus TCP. [1] [2] Many industrial Ethernet protocols use a modified media access control (MAC) layer to provide low latency and determinism. [1] Some microprocessors provide industrial Ethernet support.

  8. DNP3 - Wikipedia

    en.wikipedia.org/wiki/DNP3

    The Remote Terminal Unit is initially interrogated with what DNP3 terms an "Integrity Poll" (a combined Read of Class 1, 2, 3 and 0 data). This causes the Remote Terminal Unit to send all buffered events and also all static point data to the Master station. Following this, the Master polls for the event data by reading Class 1, Class 2 or Class 3.

  9. Talk:Modbus - Wikipedia

    en.wikipedia.org/wiki/Talk:Modbus

    "TCP MODBUS ADU = 253 bytes + MBAP (7 bytes) = 260 bytes." A total of 253 bytes for a Modbus PDU means that up to 125 registers can be read (there are no extra CRC bytes required for TCP connections). With function code 0x03 (Read Holding Registers) or 0x04 (Read Input Registers), the RESPONSE message size calculation is as follows: