The Charrière is measured by the ''outer'' diameter, and is defined as 1 Fr = 1/3 mm, and thus 1 mm = 3 Fr; therefore the diameter of a round catheter in millimetres can be determined by dividing the French size by 3. [2] The French units roughly correspond to the outer circumference of the catheter (see table below).
Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...
AN sizes range from -2 (dash two) to -32 in irregular steps, with each step equating to the OD (outside diameter) of the tubing in 1 ⁄ 16-inch increments. Therefore, a -8 AN size would be equal to 1 ⁄ 2-inch OD tube. However, this system does not specify the ID (inside diameter) of the tubing because the tube wall can vary in thickness.
In the plumbing trade, the size of copper tubing is measured by its outside diameter in millimeters. Common sizes are 15 mm and 22 mm. [7] Other sizes include 18 mm, 28 mm, 35 mm, 42 mm, 54 mm, 66.7 mm, 76.1 mm, and 108 mm outside diameters. Tubing in 8 mm and 10 mm outside diameters is called a "micro bore" and is easier to install, although ...
Iron Pipe Size (IPS or I.P.S.) pipe sizing system based on the inside diameter (ID) of pipe. It was widely used from the early 19th century to the mid 20th century and is still in use by some industries, including major PVC pipe manufacturers, as well as for some legacy drawings and equipment. The iron pipe size standard came into being early ...
Standard sizes are indicated by the nominal inner diameter in millimeters for flanges 10 through 50 mm in diameter. [2] Sizes 10, 20 and 32 are less common sizes (see Renard numbers ). Some sizes share their flange dimensions with their respective larger neighbor and use the same clamp size.
The gauge starts at the lowest gauge number of 5Ø or 00000, corresponding to the largest size of 0.500 inches (12.7 mm), and runs to the highest gauge number of 36, corresponding to the smallest size of 0.004 inches (0.10 mm). Size steps between gauges range from 0.001 inches (0.025 mm) between high gauge numbers to 0.046 inches (1.2 mm ...
A tube and pipe may be specified by standard pipe size designations, e.g., nominal pipe size, or by nominal outside or inside diameter and/or wall thickness. The actual dimensions of pipe are usually not the nominal dimensions: A 1-inch pipe will not actually measure 1 inch in either outside or inside diameter, whereas many types of tubing are ...