The Kjeldahl method or Kjeldahl digestion (Danish pronunciation: [ˈkʰelˌtɛˀl]) in analytical chemistry is a method for the quantitative determination of a sample's organic nitrogen plus ammonia/ammonium (NH 3 /NH 4 +). Without modification, other forms of inorganic nitrogen, for instance nitrate, are not included in
His laboratory technique for nitrogen and protein analysis is still the universally accepted method for this analysis. Although other methods claim to be faster and more efficient, none can cope with the variety of sizes or conditions of samples than Johan Kjeldahl's original method. Kjeldahl equipment is used extensively all over the world.
The NSI is the amount of Nitrogen in this filtered solution divided by the nitrogen in the initial sample, as measured by the Kjeldahl method. [ 3 ] The relevance of the NSI is based on the fact that proteins are the major biological source of Nitrogen: for various types of protein, there are empirical formulas which correlate the nitrogen ...
A Soxhlet extractor is a piece of laboratory apparatus [1] invented in 1879 by Franz von Soxhlet. [2] It was originally designed for the extraction of a lipid from a solid material. Typically, Soxhlet extraction is used when the desired compound has a limited solubility in a solvent, and the impurity is insoluble in that solvent. It allows for ...
The measured signal from the thermal conductivity detector for the unknown sample can then be converted into a nitrogen content. As with the Kjeldahl method, conversion of the concentration of nitrogen in a sample to the crude protein content is performed using conversion factors which depend on the particular amino acid sequence of the ...
Over time, this became a separate branch of analytical chemistry called instrumental analysis. Because of the high volume of wet chemistry that must be done in today's society and new quality control requirements, many wet chemistry methods have been automated and computerized for streamlined analysis. The manual performance of wet chemistry ...
The continuous stream of liquid samples and reagents are combined and transported in tubing and mixing coils. The tubing passes the samples from one apparatus to the other with each apparatus performing different functions, such as distillation, dialysis, extraction, ion exchange, heating, incubation, and subsequent recording of a signal.
However, on food labels the protein is calculated by the nitrogen multiplied by 6.25, because the average nitrogen content of proteins is about 16%. The Kjeldahl test is typically used because it is the method the AOAC International has adopted and is therefore used by many food standards agencies around the world, though the Dumas method is ...