When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    They are also found on some RVs for connecting to shore power. RVs in the US are equipped for 120 V 30 A or 240 V 50 A service, and use a cord to connect to a receptacle at the campsite, usually on a power pedestal with one or more receptacles providing 120 V 30 A (TT30R), 240 V 50 A (14-50R), or 120 V 15/20 A (5-20R) service.

  3. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    This allows one to choose single-phase AC power at either 110–120 volts between phase and neutral or 220–240 volts between phase and phase. Since these two modes do not need three phases there is also a dark yellow-orange four-pin connector available designed for a single-phase 110–120 or 220–240 volt load.

  4. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Lighting and general purpose receptacles are at 120 volts AC, with larger devices fed by three wire single-phase circuits at 240 volts. In commercial construction, three-phase circuits are often used. Common 3 phase configurations within a building are 208v/120 wye, 120/240 center tapped delta and 480v/277v wye. Lighting is usually fed by 277 V ...

  5. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    Closer to the customer, a distribution transformer steps the primary distribution power down to a low-voltage secondary circuit, usually 120/240 V in the US for residential customers. The power comes to the customer via a service drop and an electricity meter. The final circuit in an urban system may be less than 15 metres (50 ft) but may be ...

  6. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    Single-pole circuit breakers feed 120 V circuits from one of the 120 V buses within the panel, or two-pole circuit breakers feed 240-volt circuits from both buses. 120 V circuits are the most common, and used to power NEMA 1 and NEMA 5 outlets, and most residential and light commercial direct-wired lighting circuits.

  7. Mains electricity by country - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity_by_country

    NEMA 5-20R outlets, which are similar to type B but have a T-shaped neutral slot, are sometimes used for higher current 120 V equipment (up to 20 A). Homes are typically provided with 120/240 V split-phase power; NEMA 14-30R and 14-50R receptacles are provided on 240 V circuits for clothes dryers and electric stoves. [20] Cape Verde: C, F 220 V

  8. Power distribution unit - Wikipedia

    en.wikipedia.org/wiki/Power_distribution_unit

    A 10-outlet rack-mount PDU (front), connected to a UPS (bottom unit on right) A temporary PDU, distributing 120 volt AC power at an outdoor event Cabinet PDU with access doors open A power distribution unit ( PDU ) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking ...

  9. Mains electricity - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity

    Mains electricity or utility power, grid power, domestic power, and wall power, or, in some parts of Canada, hydro, is a general-purpose alternating-current (AC) electric power supply. It is the form of electrical power that is delivered to homes and businesses through the electrical grid in many parts of the world.