Strictly speaking, the terms grounding or earthing are meant to refer to an electrical connection to ground/earth. Bonding is the practice of intentionally electrically connecting metallic items not designed to carry electricity. This brings all the bonded items to the same electrical potential as a protection from electrical shock.
While the national wiring regulations for buildings of many countries follow the IEC 60364 terminology, in North America (United States and Canada), the term "equipment grounding conductor" refers to equipment grounds and ground wires on branch circuits, and "grounding electrode conductor" is used for conductors bonding an earth/ground rod ...
A ground connection that is missing or of inadequate capacity may not provide the protective functions as intended during a fault in the connected equipment. Extra connections between ground and circuit neutral may result in circulating current in the ground path, stray current introduced in the earth or in a structure, and stray voltage.
Electrical bonding is the practice of intentionally electrically connecting all exposed metal items not designed to carry electricity in a room or building as protection from electric shock. Bonding is also used to minimize electrical arcing between metal surfaces with electrical potential differences.
The ground loop still exists, but the two sides of the loop are close together, so stray magnetic fields induce equal currents in both sides, which cancel out. Break in the shield Create a break in the signal cable shield conductor. [5] The break should be at the load end. This is often called ground lifting. It is the simplest solution; it ...
According to the NCAA rulebook, there is no intentional grounding penalty if the quarterback throws the ball where he expects his receiver to be.
An isolated ground (IG) (or Functional Earth (FE) in European literature) is a ground connection to a local earth electrode from equipment where the main supply uses a different earthing arrangement, one of the common earthing arrangements used with domestic mains supplies.
Among TIA-607-B's list of metallic components in need of bonding are racks, enclosures, ladders, surge protectors, cable trays, routers, switches and patch panels. Following the bonding of telecom infrastructure components, the entire system must be bonded to the building's main ground, which is sometimes also referred to as a grounding ...