When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Edison-base lamp sockets (called screw shell devices in the NEC) are required to have the neutral conductor attached to the outer screw shell [NEC 200.10(C)]. [5] In actual practice, the neutral terminal is silver colored, the line and load terminals are brass or (rarely) painted black), and the grounding screw is usually colored green.

  3. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    A shared neutral is a connection in which a plurality of circuits use the same neutral connection. This is also known as a common neutral , and the circuits and neutral together are sometimes referred to as an Edison circuit .

  4. Federal Mediation and Conciliation Service (United States)

    en.wikipedia.org/wiki/Federal_Mediation_and...

    These programs continue separate operations, except for those who may wish to have FMCS administer their regional Shared Neutrals program. Annually, the Shared Neutrals Program provides workplace mediation services for hundreds of cases across more than 50 participating agencies and sub-agencies, supported by a pool of more than 250 collateral ...

  5. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    Wiring regulations govern the application of split-phase circuits so that the shared neutral can be protected from excess current. A neutral wire can be shared only by two circuits fed from opposite lines of the supply system, using circuit breakers connected by a bar so that both trip simultaneously ( [ 4 ] NEC 210.4); this prevents 120 V from ...

  6. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    The National Electrical Code (NEC), or NFPA 70, is a regionally adoptable standard for the safe installation of electrical wiring and equipment in the United States. It is part of the National Fire Code series published by the National Fire Protection Association (NFPA), a private trade association. [1]

  7. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    The neutral connection is the wider T-shaped slot on the right. All NEMA 5 devices are three-wire grounding devices (hot–neutral–ground) rated for 125 V maximum, with the 5-15, 5-20 and 5-30 being grounded versions of the 1-15, 1-20 and 1-30, respectively.

  8. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    The white 'pigtail' is a low-power neutral connection, hard-wired into the unit. Starting with the 1999 version of the National Electrical Code in the United States, and the 2002 version of the Canadian Electrical Code in Canada, the national codes require AFCIs in all circuits that feed outlets in bedrooms of dwelling units. As of the 2014 NEC ...

  9. ANSI device numbers - Wikipedia

    en.wikipedia.org/wiki/ANSI_device_numbers

    A suffix letter or number may be used with the device number; for example, suffix N is used if the device is connected to a Neutral wire (example: 59N in a relay is used for protection against Neutral Displacement); and suffixes X, Y, Z are used for auxiliary devices.