When.com Web Search

  1. Ads

    related to: 200 amp meter base with lever bypass diagram 1 wire

Search results

  1. Results From The WOW.Com Content Network
  2. Multiway switching - Wikipedia

    en.wikipedia.org/wiki/Multiway_switching

    The Carter system, also known as the Chicago system, was a method of wiring three-way switches in the era of early knob-and-tube wiring. This now-obsolete wiring method has been prohibited by the USA National Electrical Code since 1923, [ 2 ] even in new knob-and-tube installations which are still permitted under certain circumstances.

  3. Single-line diagram - Wikipedia

    en.wikipedia.org/wiki/Single-line_diagram

    A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.

  4. Reference designator - Wikipedia

    en.wikipedia.org/wiki/Reference_designator

    1A1A44J5 - Unit 1, Assembly 1, Sub-Assembly 44, Jack 5 (J5 is a connector on a box referenced as A44) 1A1A45J333 - Unit 1, Assembly 1, Sub-Assembly 45, Jack 333 (J333 is a connector on a box referenced as A45) A cable connecting these two might be: 1A1W35 - In the assembly A1 is a cable called W35. Connectors on this cable would be designated:

  5. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    A thermal–magnetic circuit breaker, which is the type found in most distribution boards in Europe and countries with a similar wiring arrangement, incorporates both techniques with the electromagnet responding instantaneously to large surges in current (such as short circuits) and the bimetallic strip responding to lesser but longer-term over ...

  6. Shunt (electrical) - Wikipedia

    en.wikipedia.org/wiki/Shunt_(electrical)

    Common accuracy specifications of such devices are ±0.1%, ±0.25% or ±0.5%. The Thomas-type double manganin walled shunt and MI type (improved Thomas-type design) were used by NIST and other standards laboratories as the legal reference of an ohm until superseded in 1990 by the quantum Hall effect .

  7. Service drop - Wikipedia

    en.wikipedia.org/wiki/Service_drop

    Each phase wire provides around 230 V to loads connected between it and the neutral. Each of the phase wires carries 50 Hz alternating current which is 120° out of phase with the other two. Several slightly different voltage standards have been used in the past as well: 220Y380, 230Y400 and 240Y415, with plans for future "harmonization ...

  8. AOL latest headlines, entertainment, sports, articles for business, health and world news.

  9. Current clamp - Wikipedia

    en.wikipedia.org/wiki/Current_clamp

    Accurate measurement of low currents (a few milliamperes) with a current transformer clamp is more difficult. The range of any given meter can be extended by passing the conductor through the jaw multiple times. For example a 0–200 A meter can be turned into a 0–20 A meter by winding the conductor 10 times around the jaw's core.