Search results
Results From The WOW.Com Content Network
With the normal untagged Ethernet frame overhead of 18 bytes and the 1500-byte payload, the Ethernet maximum frame size is 1518 bytes. If a 1500-byte IP packet is to be carried over a tagged Ethernet connection, the Ethernet frame maximum size needs to be 1522 bytes due to the larger size of an 802.1Q tagged frame.
A ping of death is a type of attack on a computer system that involves sending a malformed or otherwise malicious ping to a computer. [1] In this attack, a host sends hundreds of ping requests with a packet size that is large or illegal to another host to try to take it offline or to keep it preoccupied responding with ICMP Echo replies.
The IEEE 802.3 Ethernet standard originally mandated support for 1500-byte MTU frames, 1518 byte total frame size (1522 byte with the optional IEEE 802.1Q VLAN/QoS tag). The IEEE 802.3as update grandfathered in multiple common headers, trailers, and encapsulations by creating the concept of an envelope where up to 482 bytes of header and ...
Ping measures the round-trip time for messages sent from the originating host to a destination computer that are echoed back to the source. The name comes from active sonar terminology that sends a pulse of sound and listens for the echo to detect objects under water. [1] Ping operates by means of Internet Control Message Protocol (ICMP) packets.
The round-trip time or ping time is the time from the start of the transmission from the sending node until a response (for example an ACK packet or ping ICMP response) is received at the same node. It is affected by packet delivery time as well as the data processing delay, which depends on the load on the responding node. If the sent data ...
Ethernet packet. The SFD (start frame delimiter) marks the end of the packet preamble. It is immediately followed by the Ethernet frame, which starts with the destination MAC address. [1] In computer networking, an Ethernet frame is a data link layer protocol data unit and uses the underlying Ethernet physical layer transport mechanisms.
That value was chosen because the maximum length of the data field of an Ethernet 802.3 frame is 1500 bytes and 1536 is equivalent to the number 600 in the hexadecimal numeral system. Thus, values of 1500 and below for this field indicate that the field is used as the size of the payload of the Ethernet frame while values of 1536 and above ...
At 155 Mbit/s, a typical full-length 1,500 byte Ethernet frame would take 77.42 μs to transmit. On a lower-speed 1.544 Mbit/s T1 line, the same packet would take up to 7.8 milliseconds. A queuing delay induced by several such data packets might exceed the figure of 7.8 ms several times over.