When.com Web Search

  1. Ads

    related to: buffer reference standard ph 7.00

Search results

  1. Results From The WOW.Com Content Network
  2. Buffer solution - Wikipedia

    en.wikipedia.org/wiki/Buffer_solution

    Buffer capacity falls to 33% of the maximum value at pH = pK a ± 1, to 10% at pH = pK a ± 1.5 and to 1% at pH = pK a ± 2. For this reason the most useful range is approximately p K a ± 1. When choosing a buffer for use at a specific pH, it should have a p K a value as close as possible to that pH.

  3. Tris - Wikipedia

    en.wikipedia.org/wiki/Tris

    The useful buffer range for tris (pH 7–9) coincides with the physiological pH typical of most living organisms. This, and its low cost, make tris one of the most common buffers in the biology/biochemistry laboratory. Tris is also used as a primary standard to standardize acid solutions for chemical analysis.

  4. Acid dissociation constant - Wikipedia

    en.wikipedia.org/wiki/Acid_dissociation_constant

    Therefore, the buffer regions will be centered at about pH 1.3 and pH 4.3. The buffer regions carry the information necessary to get the pK a values as the concentrations of acid and conjugate base change along a buffer region. Between the two buffer regions there is an end-point, or equivalence point, at about pH 3.

  5. Standard hydrogen electrode - Wikipedia

    en.wikipedia.org/wiki/Standard_hydrogen_electrode

    During the early development of electrochemistry, researchers used the normal hydrogen electrode as their standard for zero potential. This was convenient because it could actually be constructed by "[immersing] a platinum electrode into a solution of 1 N strong acid and [bubbling] hydrogen gas through the solution at about 1 atm pressure".

  6. Diabetic ketoacidosis - Wikipedia

    en.wikipedia.org/wiki/Diabetic_ketoacidosis

    A 2004 statement by the European Society for Paediatric Endocrinology and the Lawson Wilkins Pediatric Endocrine Society (for children) uses slightly different cutoffs, where mild DKA is defined by pH 7.20–7.30 (bicarbonate 10–15 mmol/L), moderate DKA by pH 7.1–7.2 (bicarbonate 5–10) and severe DKA by pH<7.1 (bicarbonate below 5).

  7. Glass electrode - Wikipedia

    en.wikipedia.org/wiki/Glass_electrode

    Internal solution, usually a pH=7 buffered solution of 0.1 mol/L KCl for pH electrodes or 0.1 mol/L MCl for pM electrodes. When using the silver chloride electrode, a small amount of AgCl can precipitate inside the glass electrode. Reference electrode, usually the same type as 2. Reference internal solution, usually 3.0 mol/L KCl.

  8. Calcium carbonate - Wikipedia

    en.wikipedia.org/wiki/Calcium_carbonate

    [84] [85] Scaling is commonly observed in electrolytic chlorine generators, where there is a high pH near the cathode surface and scale deposition further increases temperature. This is one reason that some pool operators prefer borate over bicarbonate as the primary pH buffer, and avoid the use of pool chemicals containing calcium. [86]

  9. M101 howitzer - Wikipedia

    en.wikipedia.org/wiki/M101_howitzer

    The M101A1 (previously designated Howitzer M2A2 on Carriage M2A2) howitzer is an artillery piece developed and used by the United States.It was the standard U.S. light field howitzer in World War II and saw action in both the European and Pacific theaters and during the Korean War.