Search results

  1. Results From The WOW.Com Content Network
  2. Retardation factor - Wikipedia

    en.wikipedia.org/wiki/Retardation_factor

    An R F value will always be in the range 0 to 1; if the substance moves, it can only move in the direction of the solvent flow, and cannot move faster than the solvent. For example, if particular substance in an unknown mixture travels 2.5 cm and the solvent front travels 5.0 cm, the retardation factor would be 0.50.

  3. Chromatographic response function - Wikipedia

    en.wikipedia.org/wiki/Chromatographic_response...

    The CRFs in thin layer chromatography characterize the equal-spreading of the spots. The ideal case, when the RF of the spots are uniformly distributed in <0,1> range (for example 0.25,0.5 and 0.75 for three solutes) should be characterized as the best situation possible.

  4. Response factor - Wikipedia

    en.wikipedia.org/wiki/Response_factor

    Response factor, usually in chromatography and spectroscopy, is the ratio between a signal produced by an analyte, and the quantity of analyte which produces the signal. Ideally, and for easy computation, this ratio is unity (one).

  5. Retention distance - Wikipedia

    en.wikipedia.org/wiki/Retention_distance

    In contrast to the similar concept called Retention uniformity, R d is sensitive to R f values close to 0 or 1, or close to themselves. If two values are not separated, it is equal to 0. For example, the R f values (0,0.2,0.2,0.3) (two compounds not separated at 0.2 and one at the start ) result in R D equal to 0, but R U equal to 0.3609.

  6. Paper chromatography - Wikipedia

    en.wikipedia.org/wiki/Paper_chromatography

    It is used in chromatography to quantify the amount of retardation of a sample in a stationary phase relative to a mobile phase. [2] R ƒ values are usually expressed as a fraction of two decimal places. If R ƒ value of a solution is zero, the solute remains in the stationary phase and thus it is immobile.

  7. Relative permittivity - Wikipedia

    en.wikipedia.org/wiki/Relative_permittivity

    The following table gives some typical values. ... (RF) transmission lines ... sample preparation and chromatography techniques in analytical chemistry.

  8. SDS-PAGE - Wikipedia

    en.wikipedia.org/wiki/SDS-PAGE

    The relative mobility (called Rf value or Rm value) is defined as the distance migrated by the protein band divided by the distance migrated by the buffer front. The distances are each measured from the beginning of the separation gel. The migration of the buffer front roughly corresponds to the migration of the dye contained in the sample buffer.

  9. Triple quadrupole mass spectrometer - Wikipedia

    en.wikipedia.org/wiki/Triple_quadrupole_mass...

    A triple quadrupole mass spectrometer (TQMS), is a tandem mass spectrometer consisting of two quadrupole mass analyzers in series, with a (non-mass-resolving) radio frequency (RF)–only quadrupole between them to act as a cell for collision-induced dissociation. This configuration is often abbreviated QqQ, here Q 1 q 2 Q 3.