When.com Web Search

  1. Ads

    related to: how to calculate circulator size of water tank per person for 3 ton furnace

Search results

  1. Results From The WOW.Com Content Network
  2. Hydronic balancing - Wikipedia

    en.wikipedia.org/wiki/Hydronic_balancing

    Hydronic balancing, also called hydraulic balancing, is the process of optimizing the distribution of water in a building's hydronic heating or cooling system by equalizing the system pressure. In a balanced system every radiator is set to receive the proper amount of fluid in order to provide the intended indoor climate at optimum energy ...

  3. Population equivalent - Wikipedia

    en.wikipedia.org/wiki/Population_equivalent

    For example, a commonly used definition used in Europe is: 1 PE equates to 60 gram of BOD per person per day, and it also equals 200 liters of sewage per day. [3] [4] [5] In the United States, a figure of 80 grams BOD per day is normally used. [6]: 171 If the base value is taken as 60 grams of BOD per person per day, then the equation to ...

  4. Circulator pump - Wikipedia

    en.wikipedia.org/wiki/Circulator_pump

    The traditional hot water recirculation system uses the existing cold water line as return line from the point of use located farthest from the hot water tank back to the hot water tank. The first of two system types has a pump mounted at the hot water heater while a "normally open" thermostatic control valve gets installed at the farthest ...

  5. Forced circulation boiler - Wikipedia

    en.wikipedia.org/wiki/Forced_circulation_boiler

    In water tube boilers, the way the water is recirculated inside the boiler before becoming steam can be described as either natural circulation or forced circulation. In a water tube boiler, the water is recirculated inside until the vapor pressure of the water overcomes the vapor pressure inside the stream drum and becomes saturated steam.

  6. Cooling capacity - Wikipedia

    en.wikipedia.org/wiki/Cooling_capacity

    Cooling capacity is the measure of a cooling system's ability to remove heat. [1] It is equivalent to the heat supplied to the evaporator/boiler part of the refrigeration cycle and may be called the "rate of refrigeration" or "refrigeration capacity".

  7. Pressure tank - Wikipedia

    en.wikipedia.org/wiki/Pressure_tank

    The diaphragm or bladder may itself exert a pressure on the water, but it is usually small and will be neglected in the following discussion. Case 1 is an empty tank at the charging pressure P c (gauge). The total volume of the tank is V t. Case 2 is a tank in use, with the air pressure at pressure P (gauge) and a water volume of V

  8. Boiler feedwater pump - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater_pump

    Feedwater pumps range in size up to many kilowatts and the electric motor is usually separated from the pump body by some form of mechanical coupling. Large industrial condensate pumps may also serve as the feedwater pump. In either case, to force the water into the boiler, the pump must generate sufficient pressure to overcome the steam ...

  9. Circulating water plant - Wikipedia

    en.wikipedia.org/wiki/Circulating_Water_Plant

    A circulating water plant or circulating water system is an arrangement of flow of water in fossil-fuel power station, chemical plants and in oil refineries. The system is required because various industrial process plants uses heat exchanger , and also for active fire protection measures.