Ads
related to: typical garage slab thickness requirements
Search results
Results From The WOW.Com Content Network
Compared to traditional solid slabs, the reduced self-weight of biaxial slabs allows for longer spans and/or reduced deck thickness. The overall mass of concrete can be reduced by 35–50% depending on the design, [ 1 ] as a consequence of reduced slab mass, as well as lower requirements for vertical structure and foundations.
A multistorey car park in Hradec Králové, Czech Republic The interior of a shopping mall's parking garage in Kungälv, Sweden. A multistorey car park [1] [2] (Commonwealth English) or parking garage (American English), [1] also called a multistorey, [3] parking building, parking structure, parkade (), parking ramp, parking deck, or indoor parking, is a building designed for car, motorcycle ...
The precast concrete slab has tubular voids extending the full length of the slab, typically with a diameter equal to the 2/3–3/4 the thickness of the slab. This makes the slab much lighter than a massive solid concrete floor slab of equal thickness or strength. The reduced weight also lowers material and transportation costs.
A concrete slab is a common structural element of modern buildings, consisting of a flat, horizontal surface made of cast concrete. Steel-reinforced slabs, typically between 100 and 500 mm thick, are most often used to construct floors and ceilings, while thinner mud slabs may be used for exterior paving (see below). [1] [2]
The CBR test is a penetration test in which a standard piston, with a diameter of 50 mm (1.969 in), is used to penetrate the soil at a standard rate of 1.25 mm/minute. Although the force increases with the depth of penetration, in most cases, it does not increase as quickly as it does for the standard crushed rock, so the ratio decreases.
The underside of a waffle slab, showing the grid like structure. A waffle slab or two-way joist slab is a concrete slab made of reinforced concrete with concrete ribs running in two directions on its underside. [1] The name waffle comes from the grid pattern created by the reinforcing ribs.
Waffle slab foundations adhere to International Building Code requirements. By 2008, most states put into effect the changes adopted in the 2006 IBC and, in regards to foundations, the on-grade mat foundation has become a more attractive design because, as an engineered system, it already accommodates the 2008 design recommendations, and required no major modifications to bring it into compliance.
Slab-on-grade foundations should not be used in areas with expansive clay soil. While elevated structural slabs actually perform better on expansive clays, it is generally accepted by the engineering community that slab-on-grade foundations offer the greatest cost-to-performance ratio for tract homes. Elevated structural slabs are generally ...