When the box is activated by turning a knob or pulling a hook, a spring-loaded wheel turns, tapping out a pulsed electrical signal corresponding to the box's number. [1] A receiver at fire headquarters announces the alarm through flashing lights or tones, or via a pen recorder, and the box number is matched to a list of box locations.
Coded panels were the earliest type of central fire alarm control, and were made during the 1800s to the 1970s. A coded panel is similar in many ways to a modern conventional panel (described below), except each zone was connected to its own code wheel, which, depending on the way the panel was set up, would either do sets of four rounds of code until the initiating pull station was reset ...
This considerably smaller device was produced by the Gamewell Corporation, of Newton, Massachusetts, for use as a municipal alarm, especially at fire stations, to alert firefighters and the public during emergencies. Many Gamewell diaphone systems remain in use today. [13]
For premium support please call: 800-290-4726 more ways to reach us
They also rebranded coded fire alarm stations from Holtzer-Cabot. From the 1930s to the 1960s, Faraday was known as " Sperti -Faraday", and the company moved to Adrian, Michigan . [ 1 ] From the late 1960s up until present, many companies rebranded Faraday's popular line of notification appliances, including Simplex , Standard Electric Time ...
Many modern fire alarm pull stations are single-action and only require the user to pull down a handle to sound the alarm. Other fire alarm pull stations are dual-action, and as such require the user to perform a second task before pulling down, such as lifting or pushing in a panel on the station or breaking a glass panel with an attached hammer.
The EN 54 series of standards covers the following topics and product groups related to fire detection and fire alarm systems: [6] [7] Introduction: the introduction to the series of standards contains a diagram of a fire alarm system as well as numerous definitions of terms that are used in the other parts of the series of standards.
Although an intruder alarm panel may also have these detectors connected, it may not meet all the local fire code requirements of a fire alarm system. Traditional smoke detectors are ionization smoke detectors which create an electric current between two metal plates, which sound an alarm when disrupted by smoke entering the chamber.