In electronics testing and servicing, an isolation transformer is a 1:1 (under load) power transformer used for safety. Without it, exposed live metal in a device under test is at a hazardous voltage relative to grounded objects such as a heating radiator or oscilloscope ground lead (a particular hazard with some old vacuum-tube equipment with ...
Transformers are used in power converters to incorporate electrical isolation and voltage step-down or step up. The secondary circuit is floating, when you touch the secondary circuit, you merely drag its potential to your body's potential or the earth's potential. There will be no current flowing through your body.
In electrical engineering, isolated-phase bus (IPB), also known as phase-isolated bus (PIB) in some countries, is a method of construction for circuits carrying very large currents, typically between a generator and its step-up transformer in a steam or large hydroelectric power plant. Isolated phase bus during installation at the Bui Dam Ghana ...
While transformers are usually used to step up or step down the voltages, isolation transformers with a 1:1 ratio are used mostly in safety applications while keeping the voltage the same. If two electronic systems have a common ground, they are not galvanically isolated. The common ground might not normally and intentionally have connection to ...
The power is transmitted from one end to another with the help of step-up and step down transformer. Most transmission lines are high-voltage three-phase alternating current (AC), although single phase AC is sometimes used in railway electrification systems .
Supplies with transformers isolate the incoming power supply from the powered device and so allow metalwork of the enclosure to be grounded safely. Dangerous if primary/secondary insulation breaks down, unlikely with reasonable design. Transformerless mains-operated supply are not isolated and therefore dangerous when exposed. In both linear ...