Using metric units, the volumetric flow rate of a nozzle is given by =, [1] [2] where q is the flow rate in litres per minute ( l/min ), p is the pressure at the nozzle in bar and K is the K-factor is given in units of (/) /.
A ground source heat pump (also geothermal heat pump) is a heating/cooling system for buildings that use a type of heat pump to transfer heat to or from the ground, taking advantage of the relative constancy of temperatures of the earth through the seasons.
A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...
The 2002 edition of the NFPA #13 standard, section 3.6.1 defines quick response sprinklers as having a response time index (RTI) of 50 (meter-seconds) 1/2 or less. RTI is a measure of how thermally responsive the heat-responsive element of the sprinkler is, measured as the time needed to raise the temperature of the sprinkler bulb to 63% of the ...
The majority of guidance available for design of heat and smoke building vents installed in buildings is restricted to nonsprinklered, single-story buildings. [4] This is partly a historical consequence of the installation of heat and smoke vents following the August 1953 General Motors, Livonia, MI major fire in a nonsprinklered manufacturing facility which effectively stopped the production ...
The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance. [3]
A jockey pump is sized for a flow less than one sprinkler in order to ensure a system pressure drop significant enough to start the main fire pump. Jockey pumps are typically small multistage centrifugal pumps, and do not have to be listed or certified for fire system application. The control equipment for jockey pumps may however carry approvals.
Article in American Machinist, Vol. 26 states the author noted that one of the largest valve manufacturers in the country had no less than 270 different thread gauges for 2 + 1 ⁄ 2-inch fire hose couplers alone; that a local shop that served only the fire fighting industry had 150 such gauges hanging on its wall; and that in 1899 Pratt ...