When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. North American Fire Hose Coupler Incompatibilities - Wikipedia

    en.wikipedia.org/wiki/North_American_Fire_Hose...

    1 + 12-inch hose with 1 + 12-11.5NPSH ASME threads instead of NFPA threads in the U.S. and Canada, without any regulation specifying its use, and contrary to NFPA 1963. [9] This is perhaps a direct result of the 1918 War Industries Board recommendation noted above, combined with 1 + 12 -inch 1.5-9 NH NFPA couplings not being ...

  3. Heat pump - Wikipedia

    en.wikipedia.org/wiki/Heat_pump

    A ground source heat pump (also geothermal heat pump) is a heating/cooling system for buildings that use a type of heat pump to transfer heat to or from the ground, taking advantage of the relative constancy of temperatures of the earth through the seasons.

  4. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...

  5. Fire sprinkler - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler

    The 2002 edition of the NFPA #13 standard, section 3.6.1 defines quick response sprinklers as having a response time index (RTI) of 50 (meter-seconds) 1/2 or less. RTI is a measure of how thermally responsive the heat-responsive element of the sprinkler is, measured as the time needed to raise the temperature of the sprinkler bulb to 63% of the ...

  6. Heat and smoke vent - Wikipedia

    en.wikipedia.org/wiki/Heat_and_smoke_vent

    The majority of guidance available for design of heat and smoke building vents installed in buildings is restricted to nonsprinklered, single-story buildings. [4] This is partly a historical consequence of the installation of heat and smoke vents following the August 1953 General Motors, Livonia, MI major fire in a nonsprinklered manufacturing facility which effectively stopped the production ...

  7. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance. [3]

  8. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    Using metric units, the volumetric flow rate of a nozzle is given by =, [1] [2] where q is the flow rate in litres per minute ( l/min ), p is the pressure at the nozzle in bar and K is the K-factor is given in units of (/) /.

  9. Center-pivot irrigation - Wikipedia

    en.wikipedia.org/wiki/Center-pivot_irrigation

    Center-pivot irrigation (sometimes called central pivot irrigation), also called water-wheel and circle irrigation, is a method of crop irrigation in which equipment rotates around a pivot and crops are watered with sprinklers. [1] [2] A circular area centered on the pivot is irrigated, often creating a circular pattern in crops when viewed ...