When.com Web Search

  1. Ads

    related to: sprinklers not enough pressure to pump 2 1/2 package heat pump 2 1 2 ton in pounds

Search results

  1. Results From The WOW.Com Content Network
  2. North American Fire Hose Coupler Incompatibilities - Wikipedia

    en.wikipedia.org/wiki/North_American_Fire_Hose...

    Article in American Machinist, Vol. 26 states the author noted that one of the largest valve manufacturers in the country had no less than 270 different thread gauges for 2 + 12-inch fire hose couplers alone; that a local shop that served only the fire fighting industry had 150 such gauges hanging on its wall; and that in 1899 Pratt ...

  3. Heat and smoke vent - Wikipedia

    en.wikipedia.org/wiki/Heat_and_smoke_vent

    The majority of guidance available for design of heat and smoke building vents installed in buildings is restricted to nonsprinklered, single-story buildings. [4] This is partly a historical consequence of the installation of heat and smoke vents following the August 1953 General Motors, Livonia, MI major fire in a nonsprinklered manufacturing facility which effectively stopped the production ...

  4. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...

  5. Fire sprinkler - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler

    The 2002 edition of the NFPA #13 standard, section 3.6.1 defines quick response sprinklers as having a response time index (RTI) of 50 (meter-seconds) 1/2 or less. RTI is a measure of how thermally responsive the heat-responsive element of the sprinkler is, measured as the time needed to raise the temperature of the sprinkler bulb to 63% of the ...

  6. Ground source heat pump - Wikipedia

    en.wikipedia.org/wiki/Ground_source_heat_pump

    Annual greenhouse gas (GHG) savings from using a ground source heat pump instead of a high-efficiency furnace in a detached residence (assuming no specific supply of renewable energy) Country Electricity CO 2 Emissions Intensity GHG savings relative to natural gas heating oil electric heating; Canada: 223 ton/GWh [36] [37] [38] 2.7 ton/yr: 5.3 ...

  7. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance.

  8. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    Using metric units, the volumetric flow rate of a nozzle is given by =, [1] [2] where q is the flow rate in litres per minute ( l/min ), p is the pressure at the nozzle in bar and K is the K-factor is given in units of (/) /.

  9. Heat pump - Wikipedia

    en.wikipedia.org/wiki/Heat_pump

    Specifically, the heat pump transfers thermal energy using a heat pump and refrigeration cycle, cooling the cool space and warming the warm space. [1] In winter a heat pump can move heat from the cool outdoors to warm a house; the pump may also be designed to move heat from the house to the warmer outdoors in summer.