When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Optical beam smoke detector - Wikipedia

    en.wikipedia.org/wiki/Optical_beam_smoke_detector

    An optical beam smoke detector is a device that uses a projected beam of light to detect smoke across large areas, [1] typically as an indicator of fire. [2] They are used to detect fires in buildings where standard point smoke detectors would either be uneconomical [ 3 ] or restricted for use by the height of the building.

  3. Optical spectrometer - Wikipedia

    en.wikipedia.org/wiki/Optical_spectrometer

    The first spectrographs used photographic paper as the detector. The plant pigment phytochrome was discovered using a spectrograph that used living plants as the detector. More recent spectrographs use electronic detectors, such as CCDs which can be used for both visible and UV light. The exact choice of detector depends on the wavelengths of ...

  4. Elastic recoil detection - Wikipedia

    en.wikipedia.org/wiki/Elastic_recoil_detection

    Once the ion beam has ionized target sample atoms, the sample ions are recoiled toward the detector. The beam ions are scattered at an angle that does not permit them to reach the detector. The sample ions pass through an entrance window of the detector, and depending on the type of detector used, the signal is converted into a spectrum.

  5. Multiangle light scattering - Wikipedia

    en.wikipedia.org/wiki/Multiangle_light_scattering

    Most important among them is a collimated or focused light beam (usually from a laser source producing a collimated beam of monochromatic light) that illuminates a region of the sample. In modern instruments, the beam is generally plane-polarized perpendicular to the plane of measurement, though other polarizations may be used especially when ...

  6. Fluorometer - Wikipedia

    en.wikipedia.org/wiki/Fluorometer

    Within the machine the transducer that detects fluorescence created from the upper beam is located a distance away from the sample and at a 90-degree angle from the incident, upper beam. The machine is constructed like this to decrease the stray light from the upper beam that may strike the detector. The optimal angle is 90 degrees.

  7. Mössbauer spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Mössbauer_spectroscopy

    In its most common form, Mössbauer absorption spectroscopy, a solid sample is exposed to a beam of gamma radiation, and a detector measures the intensity of the beam transmitted through the sample. The atoms in the source emitting the gamma rays must be of the same isotope as the atoms in the sample absorbing them.

  8. Spectronic 20 - Wikipedia

    en.wikipedia.org/wiki/Spectronic_20

    Before testing a sample, the Spectronic 20 is calibrated using a blank solution, which is the pure solvent that is used in the experimental sample. It is typically water or an organic solvent. In this calibration, the transmittance is set at 100% using the calibration knob of the instrument (the amplifier control knob in the figure at right).

  9. Ion beam analysis - Wikipedia

    en.wikipedia.org/wiki/Ion_beam_analysis

    The configuration of the ion beam apparatus can be changed and made more complex with the incorporation of additional components. The techniques for ion beam analysis are designed for specific purposes. Some techniques and ion sources are shown in table 1. Detector types and arrangements for ion beam techniques are shown in table 2.