When.com Web Search

  1. Ads

    related to: is corsair 4000d airflow good for work at home

Search results

  1. Results From The WOW.Com Content Network
  2. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.

  3. Centrifugal fan - Wikipedia

    en.wikipedia.org/wiki/Centrifugal_fan

    Figure 1: Components of a centrifugal fan An external motor belt driven inline centrifugal fan discharging inline to the exterior of a building through a duct. Unlike non-inline/non-concentric impeller casing design with a cutoff blade above, the concentrically symetric cylinder casing and impeller geometry of inline type redirects the outflow around so that it is parallel to the inflow of gases.

  4. Axial fan design - Wikipedia

    en.wikipedia.org/wiki/Axial_fan_design

    The air flow capacities of the fans are compared and connected in same outlet or same inlet conditions. This causes noise , specifically referred to as Beating in case of fans in parallel. To avoid beating use is made of differing inlet conditions, differences in rotational speeds of the fans , etc.

  5. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    A new parameter, effective Air Changes per Hour (called ACHH by Mojtaba Zabihi et. al. [8]), which incorporates both the flow rate and large-scale airflow patterns, could provide a more accurate measure of how efficiently air is supplied and circulated within a room. This is particularly important for effectively managing airborne disease spread.

  6. Passive ventilation - Wikipedia

    en.wikipedia.org/wiki/Passive_ventilation

    The device was found to provide sufficient ventilation air flow for a single family home and heat recovery with an efficiency around 40%. The device was however found to be too large and heavy to be practical, and the heat recovery efficiency too low to be competitive with mechanical systems of the time. [8]

  7. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    CFM25 is defined as the air flow (in cubic feet per minute) needed to create a 25 Pascal pressure change in the ductwork. CFM25 is one of the most basic measurements of ductwork airtightness. A pressure of 25 Pa is equal to 0.1 inches (0.25 cm) of water column.

  8. Bypass ratio - Wikipedia

    en.wikipedia.org/wiki/Bypass_ratio

    The bypass ratio (BPR) of a turbofan engine is the ratio between the mass flow rate of the bypass stream to the mass flow rate entering the core. [1] A 10:1 bypass ratio, for example, means that 10 kg of air passes through the bypass duct for every 1 kg of air passing through the core.

  9. Constant air volume - Wikipedia

    en.wikipedia.org/wiki/Constant_air_volume

    In a simple CAV system, the supply air flow rate is constant, but the supply air temperature is varied to meet the thermal loads of a space. [1] Most CAV systems are small, and serve a single thermal zone. However, variations such as CAV with reheat, CAV multizone, and CAV primary-secondary systems can serve multiple zones and larger buildings.