Foil or "reflective foil laminate"s (RFL). Foil-faced polyurethane or foil-faced polyisocyanurate panels. Foil-faced polystyrene. This laminated, high density EPS is more flexible than rigid panels, works as a vapor barrier, and works as a thermal break. Uses include the underside of roof sheathing, ceilings, and on walls.
Foil-faced polyisocyanurate rigid panel (pentane-expanded) initial 2.54: 1 1.20: 6.8: 55 [3] Foil-faced polyisocyanurate rigid panel (pentane-expanded) aged 5–10 years 2.54: 1 0.97: 5.5: 38 Polyisocyanurate spray foam 2.54: 1 0.76–1.46: 4.3–8.3: 30–57 Closed-cell polyurethane spray foam 2.54: 1 0.97–1.14: 5.5–6.5: 38–45 Phenolic ...
A vacuum insulated panel (VIP) is a form of thermal insulation consisting of a gas-tight enclosure surrounding a rigid core, from which the air has been evacuated. It is used in building construction, refrigeration units, and insulated shipping containers to provide better insulation performance than conventional insulation materials.
In order to accomplish small gas cell formation in man-made thermal insulation, glass and polymer materials can be used to trap air in a foam-like structure. This principle is used industrially in building and piping insulation such as , cellulose, rock wool, polystyrene foam (styrofoam), urethane foam, vermiculite, perlite, and cork. Trapping ...
[52] [53] The Solar Heat Gain Co-efficient (SHGC) [54] (a measure of solar heat transmittance) of standard single glazing can be around 78–85%. Solar gain can be reduced by adequate shading from the sun, light coloured roofing, spectrally selective (heat-reflective) paints and coatings and, various types of insulation for the rest of the ...
In the case of SIPs, the creep potential of OSB faced SIPs with EPS or polyurethane foam cores has been studied and creep design recommendations exist. [3] [4] The long-term effects of using unconventional facing and core materials require material specific testing to quantify creep design values.
Installed faced fiberglass batt insulation with its R-value visible (R-21) [1]. The R-value is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3]
Some studies show that radiant barriers can reduce cooling costs 5% to 10% when used in a warm, sunny climate. The reduced heat gain may even allow for a smaller air conditioning system. In cool climates, however, it's usually more cost-effective to install more thermal insulation than to add a radiant barrier. [16]