When.com Web Search

  1. Ad

    related to: pressure transmitter calibration procedure diagram worksheet answers 1 4

Search results

  1. Results From The WOW.Com Content Network
  2. Deadweight tester - Wikipedia

    en.wikipedia.org/wiki/Deadweight_tester

    A dead weight tester (DWT) is a calibration standard method that uses a piston cylinder on which a load is placed to make an equilibrium with an applied pressure underneath the piston. Deadweight testers are secondary standards which means that the pressure measured by a deadweight tester is defined through other quantities: length, mass and ...

  3. Current loop - Wikipedia

    en.wikipedia.org/wiki/Current_loop

    The pressure transmitter modulates the current on the loop to send the signal to the strip chart recorder, but does not in itself supply power to the loop and so is passive. Another loop may contain two passive chart recorders, a passive pressure transmitter, and a 24 V battery (the battery is the active device). Note that a 4-wire instrument ...

  4. Pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Pressure_measurement

    The back side shows the circuitry, and rectangular contact pads at top and bottom. Size: 4×4 mm. A pressure sensor is a device for pressure measurement of gases or liquids. Pressure sensors can alternatively be called pressure transducers, pressure transmitters, pressure senders, pressure indicators, piezometers and manometers, among other names.

  5. Small arms ammunition pressure testing - Wikipedia

    en.wikipedia.org/wiki/Small_arms_ammunition...

    [4] [5] [6] The Kistler ballistic pressure measurement sensor 6215 has a maximum working pressure of 600 MPa (87,023 psi) and is mounted recessed inside the cartridge case (the face of high-pressure sensor does not contact the cartridge case) and requires that the test cartridge case have a hole drilled in it prior to testing. The test ...

  6. Highway Addressable Remote Transducer Protocol - Wikipedia

    en.wikipedia.org/wiki/Highway_Addressable_Remote...

    The HART Communication Protocol (Highway Addressable Remote Transducer) is a hybrid analog+digital industrial automation open protocol. Its most notable advantage is that it can communicate over legacy 4–20 mA analog instrumentation current loops, sharing the pair of wires used by the analog-only host systems.

  7. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...

  8. Flow measurement - Wikipedia

    en.wikipedia.org/wiki/Flow_measurement

    The Dall tube is a shortened version of a Venturi meter, with a lower pressure drop than an orifice plate. As with these flowmeters the flow rate in a Dall tube is determined by measuring the pressure drop caused by restriction in the conduit. The pressure differential is typically measured using diaphragm pressure transducers with digital readout.

  9. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]