When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Flow table test - Wikipedia

    en.wikipedia.org/wiki/Flow_table_test

    The flow table test or slump-flow test is a method to determine consistency of fresh concrete. Flow table test is also used to identify transportable moisture limit of solid bulk cargoes. [ 1 ] It is used primarily for assessing concrete that is too fluid (workable) to be measured using the slump test , because the concrete will not retain its ...

  3. Concrete slump test - Wikipedia

    en.wikipedia.org/wiki/Concrete_slump_test

    The test is carried out using a metal mould in the shape of a conical frustum known as a slump cone or Abrams cone, that is open at both ends and has attached handles.The tool typically has an internal diameter of 100 millimetres (3.9 in) at the top and of 200 millimetres (7.9 in) at the bottom with a height of 305 millimetres (12.0 in).The cone is placed on a hard non-absorbent surface.

  4. Concrete block - Wikipedia

    en.wikipedia.org/wiki/Concrete_block

    A pallet of "8-inch" concrete blocks An interior wall of painted concrete blocks Concrete masonry blocks A building constructed with concrete masonry blocks. A concrete block, also known as a cinder block in North American English, breeze block in British English, concrete masonry unit (CMU), or by various other terms, is a standard-size rectangular block used in building construction.

  5. Eurocode 2: Design of concrete structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_2:_Design_of...

    EN 1992-1-2 deals with the design of concrete structures for the accidental situation of fire exposure and is intended to be used in conjunction with EN 1992-1-1 and EN 1991-1-2. This part 1-2 only identifies differences from, or supplements to, normal temperature design. Part 1-2 of EN 1992 deals only with passive methods of fire protection.

  6. Ready-mix concrete - Wikipedia

    en.wikipedia.org/wiki/Ready-mix_concrete

    Cracking and shrinkage. Concrete shrinks as it cures. It can shrink 116 inch (1.6 mm) over a 10-foot long area (3.05 meters). This causes stress internally on the concrete and must be accounted for by the engineers and finishers placing the concrete, and may require the use of steel reinforcement or pre-stressed concrete elements where ...

  7. Properties of concrete - Wikipedia

    en.wikipedia.org/wiki/Properties_of_concrete

    All concrete structures will crack to some extent, due to shrinkage and tension. Concrete which is subjected to long-duration forces is prone to creep. The density of concrete varies, but is around 2,400 kilograms per cubic metre (150 lb/cu ft). [1] Reinforced concrete is the most common form of concrete.

  8. Ex-Abercrombie & Fitch CEO has dementia, lawyers say - AOL

    www.aol.com/ex-abercrombie-fitch-ceo-dementia...

    The former CEO of Abercrombie & Fitch (A&F) has dementia and late onset Alzheimer's disease, his legal team has said in a court document filed in New York. Lawyers for Mike Jeffries have requested ...

  9. Reinforced concrete structures durability - Wikipedia

    en.wikipedia.org/wiki/Reinforced_concrete...

    The humidity content of concrete is one of the main influencing factors of CO 2 diffusion in concrete. If concrete pores are completely and permanently saturated (for instance in submerged structures) CO 2 diffusion is prevented. On the other hand, for completely dry concrete, the chemical reaction of carbonation cannot occur.