A firestop or fire-stopping is a form of passive fire protection that is used to seal around openings and between joints in a fire-resistance-rated wall or floor assembly. Firestops are designed to maintain the fire-resistance rating of a wall or floor assembly intended to impede the spread of fire and smoke.
Fire-resistance rated wall assembly with fire door, cable tray penetration and intumescent cable coating. Passive fire protection (PFP) is components or systems of a building or structure that slows or impedes the spread of the effects of fire or smoke without system activation, and usually without movement. [1]
A penetration, in firestopping, is an opening, such as one created by the use of a cast-in-place sleeve, in a wall or floor assembly required to have a fire-resistance rating, for the purpose of accommodating the passage of a mechanical, electrical, or structural penetrant. [1] The penetration may or may not contain a firestop system.
Sprinkler branch pipe through-penetration with plastic sleeve - missing firestop in concrete fire separation. The space between the sleeve and the pipe is the annulus or annular space The annulus , or annular space , is the space between a penetrant and anything that surrounds it, such as the sides of an opening or a sleeve , as the case may be ...
A vacuum insulated panel (VIP) is a form of thermal insulation consisting of a gas-tight enclosure surrounding a rigid core, from which the air has been evacuated. It is used in building construction, refrigeration units, and insulated shipping containers to provide better insulation performance than conventional insulation materials.
While in 1976 there were roughly 100 cellulose insulation firms with 125 plants in the US, by 1978 there were more than 350 firms with more than 500 plants 1. Cellulose insulation was produced locally by small manufacturers who purchased ready-to-operate machines and offered a cheap and easy low-tech production process.
Its cloth and rubber insulation can dry out and turn brittle. [10] It may also be damaged by rodents and careless activities such as hanging objects from wiring running in accessible areas like basements or attics. Currently, the United States National Electrical Code forbids the use of loose, blown-in, or expanding foam insulation over K&T ...
The stack effect or chimney effect is the movement of air into and out of buildings through unsealed openings, chimneys, flue-gas stacks, or other purposefully designed openings or containers, resulting from air buoyancy.