When.com Web Search

  1. Ads

    related to: thyristor valve hvdc fittings

Search results

  1. Results From The WOW.Com Content Network
  2. HVDC converter - Wikipedia

    en.wikipedia.org/wiki/HVDC_converter

    As of 2012, thyristor valves had been used on over 100 HVDC schemes, with many more still under construction or being planned. The highest power rating of any single HVDC converter (twelve-pulse bridge) in operation was 2000 MW in 2010, on the ±660 kV Ningdong–Shandong scheme in China .

  3. HVDC converter station - Wikipedia

    en.wikipedia.org/wiki/HVDC_converter_station

    The converter is usually installed in a building called the valve hall. Early HVDC systems used mercury-arc valves, but since the mid-1970s, solid state devices such as thyristors have been used. Converters using thyristors or mercury-arc valves are known as line commutated converters. In thyristor-based converters, many thyristors are ...

  4. High-voltage direct current - Wikipedia

    en.wikipedia.org/wiki/High-voltage_direct_current

    The development of thyristor valves for HVDC began in the late 1960s. The first complete HVDC scheme based on thyristor was the Eel River scheme in Canada, which was built by General Electric and went into service in 1972. [17] Since 1977, new HVDC systems have used solid-state devices, in most cases thyristors. Like mercury arc valves ...

  5. Valve hall - Wikipedia

    en.wikipedia.org/wiki/Valve_hall

    A valve hall is a building which contains the valves of the static inverters of a high-voltage direct current plant. The valves consist of thyristors, or at older plants, mercury arc rectifiers. Mercury arc rectifiers are usually supported by insulators mounted on the floor, while thyristor valves may be either supported by insulators or hung ...

  6. Nelson River DC Transmission System - Wikipedia

    en.wikipedia.org/wiki/Nelson_River_DC...

    The thyristors, supplied by the German HVDC consortium (Siemens, AEG and Brown Boveri) used water cooling [10] for the first time in an HVDC project. Until that time, the relatively few HVDC schemes using thyristors had used either air cooling or, as on the Cahora Bassa project supplied by the same consortium, oil-cooling.

  7. Xiangjiaba–Shanghai HVDC system - Wikipedia

    en.wikipedia.org/wiki/Xiangjiaba–Shanghai_HVDC...

    In common with the valves at the Fulong station, the valves use 8.5 kV rated, 150 mm diameter electrically triggered thyristors. At Fengxia, each valve consists of 56 series connected thyristor levels (of which two are redundant), arranged in 8 thyristor modules of 7 thyristor levels each. [4]

  8. Shin-Shinano Frequency Converter - Wikipedia

    en.wikipedia.org/wiki/Shin-Shinano_Frequency...

    The original 1977 converter was one of the first thyristor-based HVDC schemes to be put into operation in the world and used oil-insulated, oil-cooled outdoor thyristor valves supplied by Hitachi (60 Hz end) and Toshiba (50 Hz end). A special workshop was provided on the site, in which valve maintenance (for example replacing failed thyristors ...

  9. Chandrapur back-to-back HVDC converter station - Wikipedia

    en.wikipedia.org/wiki/Chandrapur_back-to-back...

    The scheme comprises 48 thyristor valves (12 at each end of each pole) and with each thyristor valve including 54 thyristor levels in series. The thyristors are of 100 mm diameter and are rated at 5.2 kV. The thyristor valves are floor-mounted even though the station is located in a seismically active area.