IMS instruments such as microscale high-field asymmetric-waveform ion mobility spectrometry can be palm-portable for use in a range of applications including volatile organic compound (VOC) monitoring, biological sample analysis, medical diagnosis and food quality monitoring. [2]
A CATI PEMS being strapped down inside a vehicle. A portable emissions measurement system (PEMS) is a vehicle emissions testing device that is small and light enough to be carried inside or moved with a motor vehicle that is being driven during testing, rather than on the stationary rollers of a dynamometer that only simulates real-world driving.
There are various types, installed on the equipment, operated in a laboratory as part of an oil analysis programme. [2] or portable units that can be transported to site, e.g., a construction site, and then used on the machine, e.g., a bulldozer, to determine fluid cleanliness. By determining and monitoring these levels, and following a ...
In a photoionization detector, high-energy photons, typically in the vacuum ultraviolet (VUV) range, break molecules into positively charged ions. [2] As compounds enter the detector they are bombarded by high-energy UV photons and are ionized when they absorb the UV light, resulting in ejection of electrons and the formation of positively charged ions.
For the analysis of volatile compounds, a purge and trap (P&T) concentrator system may be used to introduce samples. The target analytes are extracted by mixing the sample with water and purge with inert gas (e.g. Nitrogen gas) into an airtight chamber, this is known as purging or sparging.
A gas detector is a device that detects the presence of gases in a volume of space. Gas detectors come in various form factors depending on the application. This includes handheld gas detectors, wall-mounted gas detectors, gas detectors with a built-in pump used with a probe, gooseneck gas detectors, and benchtop gas detectors.
Catalytic oxidation occurs through a chemical reaction between the VOC hydrocarbon molecules and a precious-metal catalyst bed that is internal to the oxidizer system. A catalyst is a substance that is used to accelerate the rate of a chemical reaction, allowing the reaction to occur in a normal temperature range between 340 °C (644 °F) and ...
A nondispersive infrared sensor (or NDIR sensor) is a simple spectroscopic sensor often used as a gas detector.It is non-dispersive in the fact that no dispersive element (e.g a prism or diffraction grating as is often present in other spectrometers) is used to separate out (like a monochromator) the broadband light into a narrow spectrum suitable for gas sensing.