When.com Web Search

  1. Ads

    related to: raised floor systems

Search results

  1. Results From The WOW.Com Content Network
  2. Raised floor - Wikipedia

    en.wikipedia.org/wiki/Raised_floor

    An alternative raised floor application with disposable formworks from job site in Turkey A suction-cup tile lifter has been used to remove a tile.. A raised floor (also raised flooring, access floor(ing), or raised-access computer floor) provides an elevated structural floor above a solid substrate (often a concrete slab) to create a hidden void for the passage of mechanical and electrical ...

  3. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor diffusers), located at or near floor level within the occupied space. Air returns from the room at ceiling level or the maximum allowable height above the occupied zone.

  4. Seismic base isolation - Wikipedia

    en.wikipedia.org/wiki/Seismic_base_isolation

    Seismic base isolation, also known as base isolation, [3] or base isolation system, [4] is one of the most popular means of protecting a structure against earthquake forces. [5] It is a collection of structural elements which should substantially decouple a superstructure from its substructure that is in turn resting on the shaking ground, thus ...

  5. Plenum space - Wikipedia

    en.wikipedia.org/wiki/Plenum_space

    Space between the structural ceiling and the dropped ceiling or under a raised floor is typically considered plenum; however, some drop-ceiling designs create a tight seal that does not allow for airflow and therefore may not be considered a plenum air-handling space. [1] [2]

  6. Flooring - Wikipedia

    en.wikipedia.org/wiki/Flooring

    The floor under the flooring is called the subfloor, which provides the support for the flooring. Special purpose subfloors like floating floors, raised floors or sprung floors may be laid upon another underlying subfloor which provides the structural strength. Subfloors that are below grade (underground) or ground level floors in buildings ...

  7. Water detector - Wikipedia

    en.wikipedia.org/wiki/Water_detector

    The original application was in the void created by "computer room" floors in the days of large main-frame computer systems. These use a modular, raised floor based around a structural "floor tile" usually 600 mm square and supported at the corners by pedestals.

  8. Underfloor heating - Wikipedia

    en.wikipedia.org/wiki/Underfloor_heating

    Due to their low profile, they can be installed in a thermal mass or directly under floor finishes. Electric systems can also take advantage of time-of-use electricity metering and are frequently used as carpet heaters, portable under area rug heaters, under laminate floor heaters, under tile heating, under wood floor heating, and floor warming ...

  9. Server room - Wikipedia

    en.wikipedia.org/wiki/Server_room

    This conditioned air is then discharged into the server room via strategically placed floor grilles and onwards to equipment racks. These systems are well suited to new office buildings where the design can encompass raised floors suitable for ducting to computer racks.