When.com Web Search

  1. Ad

    related to: 6' 10' steel support column dimensions drawing

Search results

  1. Results From The WOW.Com Content Network
  2. I-beam - Wikipedia

    en.wikipedia.org/wiki/I-beam

    The dimension of a wide-flange I-beam. In the United States, steel I-beams are commonly specified using the depth and weight of the beam. For example, a "W10x22" beam is approximately 10 in (254 mm) in depth with a nominal height of the I-beam from the outer face of one flange to the outer face of the other flange, and weighs 22 lb/ft (33 kg/m).

  3. Structural steel - Wikipedia

    en.wikipedia.org/wiki/Structural_steel

    Steel never turns into a liquid below this temperature. Pure Iron ('Steel' with 0% Carbon) starts to melt at 1,492 °C (2,718 °F), and is completely liquid upon reaching 1,539 °C (2,802 °F). Steel with 2.1% Carbon by weight begins melting at 1,130 °C (2,070 °F), and is completely molten upon reaching 1,315 °C (2,399 °F).

  4. Structural drawing - Wikipedia

    en.wikipedia.org/wiki/Structural_drawing

    A structural drawing, a type of engineering drawing, is a plan or set of plans and details for how a building or other structure will be built. Structural drawings are generally prepared by registered professional engineers, and based on information provided by architectural drawings. The structural drawings are primarily concerned with the ...

  5. Structural engineering - Wikipedia

    en.wikipedia.org/wiki/Structural_engineering

    The limestone blocks were often taken from a quarry near the building site and have a compressive strength from 30 to 250 MPa (MPa = Pa × 10 6). [5] Therefore, the structural strength of the pyramid stems from the material properties of the stones from which it was built rather than the pyramid's geometry.

  6. Shop drawing - Wikipedia

    en.wikipedia.org/wiki/Shop_drawing

    The Concrete Reinforcing Steel Institute (CRSI) has developed standard symbols, graphics, and formats for shop drawings and cut sheets that generally are used by reinforcing steel fabricators. [5] Each fabricator, has particular style for shop drawings and cut sheets, depending on the drafts people and Computer-aided design systems.

  7. Engineering drawing abbreviations and symbols - Wikipedia

    en.wikipedia.org/wiki/Engineering_drawing...

    CAD: computer-aided design, computer-aided drafting; cadmium [plating]: CAGE: Commercial and Government Entity [code]: A CAGE code is a unique identifier to label an entity (that is, a specific government agency or corporation at a specific site) that is a CDA, ODA, or MFR of the part defined by the drawing.

  8. Jack post - Wikipedia

    en.wikipedia.org/wiki/Jack_post

    size 2 from 6.5 feet (2.0 m) to 11 feet (3.4 m), size 3 from 8 feet (2.4 m) to 13 feet (4.0 m), size 4 from 10.5 feet (3.2 m) to 16 feet (4.9 m). The safe load for each prop depends upon the size and extension of the prop. Size 1, 2 and 3 props can take about 34 kN unextended, dropping progressively to less than half of that when fully extended.

  9. Steel design - Wikipedia

    en.wikipedia.org/wiki/Steel_design

    Steel Design, or more specifically, Structural Steel Design, is an area of structural engineering used to design steel structures. These structures include schools , houses , bridges , commercial centers , tall buildings , warehouses , aircraft , ships and stadiums .