Search results
Results From The WOW.Com Content Network
Rebar (short for reinforcement bar or reinforcing bar), known when massed as reinforcing steel or steel reinforcement, [1] is a tension device added to concrete to form reinforced concrete and reinforced masonry structures to strengthen and aid the concrete under tension.
Rebar for foundations and walls of a sewage pump station. The Paulins Kill Viaduct , Hainesburg, New Jersey, is 115 feet (35 m) tall and 1,100 feet (335 m) long, and was heralded as the largest reinforced concrete structure in the world when it was completed in 1910 as part of the Lackawanna Cut-Off rail line project.
Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.
A slab is ground-bearing if it rests directly on the foundation, otherwise the slab is suspended. [3] For multi-story buildings, there are several common slab designs (see § Design for more types): Beam and block, also referred to as rib and block, is mostly used in residential and industrial applications. This slab type is made up of pre ...
Initiation and propagation periods of steel rebar corrosion in a reinforced concrete structure (Tutti diagram). [2] [3] Initially, the chemical reactions that normally occur in the cement paste, generate an alkaline environment, bringing the solution in the cement paste pores to pH values around 13. In these conditions, passivation of steel ...
Concrete cover, in reinforced concrete, is the least distance between the surface of embedded reinforcement and the outer surface of the concrete (ACI 130). The concrete cover depth can be measured with a cover meter. The purpose of concrete cover is to protect the reinforcement from corrosion, fire, and other potential damage.
Waffle slab foundations adhere to International Building Code requirements. By 2008, most states put into effect the changes adopted in the 2006 IBC and, in regards to foundations, the on-grade mat foundation has become a more attractive design because, as an engineered system, it already accommodates the 2008 design recommendations, and required no major modifications to bring it into compliance.
Reinforcement is generally placed in areas of the concrete that are likely to be subject to tension, such as the lower portion of beams. Usually, there is a minimum of 50 mm cover, both above and below the steel reinforcement, to resist spalling and corrosion which can lead to structural instability. [122]