Ads
related to: how much concrete per post hole block calculator chart
Search results
Results From The WOW.Com Content Network
A w/c ratio higher than 0.60 is not acceptable as fresh concrete becomes "soup" [2] and leads to a higher porosity and to very poor quality hardened concrete as publicly stated by Prof. Gustave Magnel (1889-1955, Ghent University, Belgium) during an official address to American building contractors at the occasion of one of his visits in the ...
The precast concrete slab has tubular voids extending the full length of the slab, typically with a diameter equal to the 2/3–3/4 the thickness of the slab. This makes the slab much lighter than a massive solid concrete floor slab of equal thickness or strength. The reduced weight also lowers material and transportation costs.
A pallet of "8-inch" concrete blocks An interior wall of painted concrete blocks Concrete masonry blocks A building constructed with concrete masonry blocks. A concrete block, also known as a cinder block in North American English, breeze block in British English, or concrete masonry unit (CMU), or by various other terms, is a standard-size rectangular block used in building construction.
Regular concrete can typically withstand a pressure from about 10 MPa (1450 psi) to 40 MPa (5800 psi), with lighter duty uses such as blinding concrete having a much lower MPa rating than structural concrete. Many types of pre-mixed concrete are available which include powdered cement mixed with an aggregate, needing only water.
Using the ASTM D1633-00 stabilization standard, a pressed and cured block must be submerged in water for four hours. It is then pulled from the water and immediately subjected to a compression test. The blocks must score at least a 300 pound-force per square inch (p.s.i) (2 MPa) minimum.
The output obtained from a site mix concrete plant using a 8/12 mixer is 4 to 5 metric cubes per hour which is 30-60 metric cubes per hour in a ready mix concrete plant. Better handling and proper mixing practice will help reduce the consumption of cement by 10 – 12%.
The presence of rebars disturbs electrical resistivity measurement as they conduct current much better than the surrounding concrete. This is particularly the case when the concrete cover depth is less than 30 mm. In order to minimize the effect, placing the electrodes above a rebar is usually avoided, or if unavoidable, then they are placed ...
Concrete cover, in reinforced concrete, is the least distance between the surface of embedded reinforcement and the outer surface of the concrete (ACI 130). The concrete cover depth can be measured with a cover meter. The purpose of concrete cover is to protect the reinforcement from corrosion, fire, and other potential damage.