When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. NFPA 704 - Wikipedia

    en.wikipedia.org/wiki/NFPA_704

    "NFPA 704: Standard System for the Identification of the Hazards of Materials for Emergency Response" is a standard maintained by the U.S.-based National Fire Protection Association. First "tentatively adopted as a guide" in 1960, [ 1 ] and revised several times since then, it defines the " Safety Square " or " Fire Diamond " which is used to ...

  3. Lower flammability limit - Wikipedia

    en.wikipedia.org/wiki/Lower_flammability_limit

    The lower flammability limit (LFL), [1] usually expressed in volume per cent, is the lower end of the concentration range over which a flammable mixture of gas or vapour in air can be ignited at a given temperature and pressure. The flammability range is delineated by the upper and lower flammability limits. Outside this range of air/vapor ...

  4. Flammability limit - Wikipedia

    en.wikipedia.org/wiki/Flammability_limit

    Dusts also have upper and lower explosion limits, though the upper limits are hard to measure and of little practical importance. Lower flammability limits for many organic materials are in the range of 10–50 g/m 3, which is much higher than the limits set for health reasons, as is the case for the LEL of many gases and vapours. Dust clouds ...

  5. Pensky–Martens closed-cup test - Wikipedia

    en.wikipedia.org/wiki/Pensky–Martens_closed-cup...

    The sample is heated and stirred at specified rates depending on the material that is being tested. This allows the development of an equilibrium between the liquid and the air volume. The ignition source is directed into the cup at regular intervals with simultaneous interruption of stirring.

  6. Flammability diagram - Wikipedia

    en.wikipedia.org/wiki/Flammability_diagram

    Any mixture of methane and air will therefore lie on the straight line between pure methane and pure air – this is shown as the blue air-line. The upper and lower flammability limits of methane in air are located on this line, as shown (labelled UEL and LEL, respectively). The stoichiometric combustion of methane is: CH 4 + 2O 2 → CO 2 + 2H ...

  7. Limiting oxygen concentration - Wikipedia

    en.wikipedia.org/wiki/Limiting_oxygen_concentration

    For instance, to safely fill a new container or a pressure vessel with flammable gases, the atmosphere of normal air (containing 20.9 volume percent of oxygen) in the vessel would first be flushed (purged) with nitrogen or another non-flammable inert gas, thereby reducing the oxygen concentration inside the container. When the oxygen ...

  8. Hazardous Materials Identification System - Wikipedia

    en.wikipedia.org/wiki/Hazardous_Materials...

    Materials may ignite spontaneously with air (e.g., propane). 3. Materials capable of ignition under almost all normal temperature conditions. Includes flammable liquids with flash points below 73 °F (23 °C) and boiling points above 100 °F (38 °C), as well as liquids with flash points between 73 °F and 100 °F. 2.

  9. HAZMAT Class 3 Flammable liquids - Wikipedia

    en.wikipedia.org/wiki/HAZMAT_Class_3_Flammable...

    Class 3: Flammable Liquids A flammable liquid is a liquid having a flash point of not more than 60 °C (140 °F), or any material in a liquid phase with a flash point at or above 37.8 °C (100 °F) that is intentionally heated and offered for transportation or transported at or above its flash point in a bulk packaging. The following exceptions ...