Search results
Results From The WOW.Com Content Network
The EPA defines refrigerant reclamation as "Reclaim refrigerant means to reprocess refrigerant to at least the purity specified in appendix A to 40 CFR part 82, subpart F (based on AHRI Standard 700–1993, Specifications for Fluorocarbon and Other Refrigerants) and to verify this purity using the analytical methodology prescribed in appendix A ...
According to ASHRAE standard 34, the R-number of a chemical refrigerant is assigned systematically according to its molecular structure and has between two and four digits. If there are carbon -carbon multiple bonds , there are four digits in all: the number of these bonds is the first digit and the number of carbon atoms minus one (C-1) is next.
HCFC-123 is used in large tonnage centrifugal chiller applications, and is the most efficient refrigerant currently in use in the marketplace for HVAC applications. HCFC-123 is also used as a testing agent for bypass leakage of carbon adsorbers in gas filtration systems, and as the primary chemical in Halotron I fire-extinguishing agent. [2]
Dichlorodifluoromethane (R-12 or CFC-12), the most commonly used Freon brand refrigerant prior to its ban in many countries in 1996 and total ban in 2010. 1,1,1,2-Tetrafluoroethane (R-134a or HFC-134a), one of the main replacements for the formerly widespread R-12. Opteon halogenated olefins now replacing Freons in many applications.
Pentafluoroethane in a near azeotropic mixture with difluoromethane is known as R-410A, a common replacement for various chlorofluorocarbons (commonly known as Freon) in new refrigerant systems. Fire suppression systems
Because of its reduced global warming potential (GWP), R-454B is intended to be an alternative to refrigerant R-410A in new equipment. [2] [3] [4] R-454B has a GWP of 466, which is 78 percent lower than R-410A's GWP of 2088. [2] R-454B is non-toxic and mildly flammable, with an ASHRAE safety classification of A2L. In the United States, it is ...
When used as a refrigerant, R-114 is classified as a medium pressure refrigerant. The U.S. Navy uses R-114 in its centrifugal chillers in preference to R-11 to avoid air and moisture leakage into the system. While the evaporator of an R-11 charged chiller runs at a vacuum during operation, R-114 yields approximately 0 psig operating pressure in ...
A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.