When.com Web Search

  1. Ads

    related to: formula for lighting a room

Search results

  1. Results From The WOW.Com Content Network
  2. Lumen method - Wikipedia

    en.wikipedia.org/wiki/Lumen_method

    In lighting design, the lumen method, (also called zonal cavity method), is a simplified method to calculate the light level in a room.The method is a series of calculations that uses horizontal illuminance criteria to establish a uniform luminaire layout in a space.

  3. Lux - Wikipedia

    en.wikipedia.org/wiki/Lux

    The lux (symbol: lx) is the unit of illuminance, or luminous flux per unit area, in the International System of Units (SI). [1] [2] It is equal to one lumen per square metre.In photometry, this is used as a measure of the irradiance, as perceived by the spectrally unequally responding human eye, of light that hits or passes through a surface.

  4. Daylight factor - Wikipedia

    en.wikipedia.org/wiki/Daylight_factor

    Light can reach a room via through a glazed window, rooflight, or other aperture via three paths: Direct light from a patch of sky visible at the point considered, known as the sky component (SC), Light reflected from an exterior surface and then reaching the point considered, known as the externally reflected component (ERC),

  5. Foot-candle - Wikipedia

    en.wikipedia.org/wiki/Foot-candle

    A foot-candle (sometimes foot candle; abbreviated fc, lm/ft 2, or sometimes ft-c) is a non-SI unit of illuminance or light intensity. The foot-candle is defined as one lumen per square foot. This unit is commonly used in lighting layouts in parts of the world where United States customary units are used, mainly the United States. [1]

  6. Illuminance - Wikipedia

    en.wikipedia.org/wiki/Illuminance

    Illuminance diagram with units and terminology. In photometry, illuminance is the total luminous flux incident on a surface, per unit area. [1] It is a measure of how much the incident light illuminates the surface, wavelength-weighted by the luminosity function to correlate with human brightness perception. [2]

  7. 20 Ways High-End Designers Properly Light a Living Room - AOL

    www.aol.com/20-ways-high-end-designers-181400454...

    Shine a light on whatever task you need with our guide to the 20 best living room lighting ideas, approved by expert interior designers.

  8. Coefficient of utilization - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_utilization

    For example, some of the light emitted by a luminaire may exit away from the desired plane and is therefore wasted. A CU measures the light actually reaching the desired plane as a percentage of the total light produced by the fixture. The value for direct lighting varies from 0.2 to 0.5 while that of indirect lighting varies from 0.1 to 0.3

  9. Orders of magnitude (illuminance) - Wikipedia

    en.wikipedia.org/wiki/Orders_of_magnitude...

    Factor ()Multiple Value Item 0 0 lux 0 lux Absolute darkness 10 −4: 100 microlux 100 microlux: Starlight overcast moonless night sky [1]: 140 microlux: Venus at brightest [1]: 200 microlux