When.com Web Search

  1. Ad

    related to: sample preparation for ftir

Search results

  1. Results From The WOW.Com Content Network
  2. Geology applications of Fourier transform infrared spectroscopy

    en.wikipedia.org/wiki/Geology_applications_of...

    FTIR mode Sample preparation Schematic diagram Transmission FTIR: Transmission mode is the most widely used FTIR technique in geoscience due to its high analysis speed and cost-efficient characteristics. [4] The sample, either a rock or a mineral, is cut into a block and polished on both sides until a thin (typically 300 to 15 μm) wafer is ...

  3. Fourier-transform infrared spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Fourier-transform_infrared...

    Fourier transform infrared spectroscopy (FTIR) [1] is a technique used to obtain an infrared spectrum of absorption or emission of a solid, liquid, or gas. An FTIR spectrometer simultaneously collects high-resolution spectral data over a wide spectral range.

  4. Infrared spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Infrared_spectroscopy

    The sample may be one solid piece, powder or basically in any form for the measurement. For example, a piece of rock can be inserted into the sample cup and the spectrum measured from it. [citation needed] A useful way of analyzing solid samples without the need for cutting samples uses ATR or attenuated total reflectance spectroscopy. Using ...

  5. Fourier-transform spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Fourier-transform_spectroscopy

    The ratio of the "sample spectrum" to the "background spectrum" is directly related to the sample's absorption spectrum. Accordingly, the technique of "Fourier-transform spectroscopy" can be used both for measuring emission spectra (for example, the emission spectrum of a star), and absorption spectra (for example, the absorption spectrum of a ...

  6. Attenuated total reflectance - Wikipedia

    en.wikipedia.org/wiki/Attenuated_total_reflectance

    The accessibility, rapid sample turnaround and ease of use of ATR with Fourier transform infrared spectroscopy (FTIR) has led to substantial use by the scientific community. This evanescent effect only works if the crystal is made of an optical material with a higher refractive index than the sample being studied. Otherwise light is lost to the ...

  7. Mulling (spectroscopy) - Wikipedia

    en.wikipedia.org/wiki/Mulling_(spectroscopy)

    The useful range for observation of a sample in a mid-infrared spectrum when using Fluorolube as the mulling agent is 4000 cm −1 to 1300 cm −1. [ 2 ] Therefore, if possible, it is preferable to run a sample as both a Nujol mull and a Fluorolube mull.

  8. Applied spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Applied_spectroscopy

    In all three spectroscopic methods, the sample usually needs to be present in solution, which may present problems during forensic examination because it necessarily involves sampling solid from the object to be examined. In FTIR, three types of samples can be analyzed: solution , powder, or film. A solid film is the easiest and most straight ...

  9. Vibrational analysis with scanning probe microscopy - Wikipedia

    en.wikipedia.org/wiki/Vibrational_analysis_with...

    The distance between the probe and a sample is kept at a few nanometers during scanning. Figure 8: General NSOM/FTIR setup. Figure 9 is the cross-section of a NSOM/FTIR instrument. As shown below, sample is placed on a piezo-electric tube scanner, in which the x-y tube has four parts, namely x+, x-, y+ and y-.