Ad
related to: how to interpret spirometry readings for children printable free pdfamazon.com has been visited by 1M+ users in the past month
Search results
Results From The WOW.Com Content Network
To interpret the significance of peak expiratory flow measurements, a comparison is made to reference (normal, predicted) values based on measurements taken from the general population. Various reference values have been published in the literature and vary by population, ethnic group, age, sex, height and weight of the patient.
Spirometry (meaning the measuring of breath) is the most common of the pulmonary function tests (PFTs). It measures lung function, specifically the amount (volume) and/or speed (flow) of air that can be inhaled and exhaled.
The interpretation of tests depends on comparing the patients values to published normals from previous studies. Deviation from guidelines can result in false-positive or false negative test results, even though only a small minority of pulmonary function laboratories followed published guidelines for spirometry, lung volumes and diffusing ...
Output of a spirometer. Vital capacity (VC) is the maximum amount of air a person can expel from the lungs after a maximum inhalation.It is equal to the sum of inspiratory reserve volume, tidal volume, and expiratory reserve volume.
Preconceived notions that 'white' people have greater pulmonary function are embedded in spirometer measurement interpretation and have only been reinforced through this medical stereotyping. In the United States, spirometers use correction factors of 10-15% for those identified as 'black' and 4-6% for those identified as 'Asian.' [ 6 ]
This test involves measuring the partial pressure difference between inspired and expired carbon monoxide. It relies on the strong affinity and large absorption capacity of red blood cells for carbon monoxide and thus demonstrates gas uptake by the capillaries that are less dependent on cardiac output. [3]
Bear in mind, however, that this number does not apply to children, and that it can differ depending on the patient's native result; small patient's with pulmonary fibrosis, restrictive lung disease etc. will have a measurably lower FEV1 than healthy average-sized adults. This can give a false positive result of the test.
The helium dilution technique is the way of measuring the functional residual capacity of the lungs (the volume left in the lungs after normal expiration).. This technique is a closed-circuit system where a spirometer is filled with a mixture of helium (He) and oxygen.