When.com Web Search

  1. Ads

    related to: positive pressure vs negative pressure hvac

Search results

  1. Results From The WOW.Com Content Network
  2. Positive pressure - Wikipedia

    en.wikipedia.org/wiki/Positive_pressure

    Positive pressure is a pressure within a system that is greater than the environment that surrounds that system. Consequently, if there is any leak from the positively pressured system, it will egress into the surrounding environment. This is in contrast to a negative pressure room, where air is sucked in. [1] [2]

  3. Stack effect - Wikipedia

    en.wikipedia.org/wiki/Stack_effect

    This presents a situation where floors underneath the neutral axis of the building have a net negative pressure, whereas floors above the neutral axis have a net positive pressure. The net negative pressure on lower floors can induce outdoor air to infiltrate the building through doors, windows, or ductwork without backdraft dampers.

  4. Negative room pressure - Wikipedia

    en.wikipedia.org/wiki/Negative_room_pressure

    Inside view of a negative pressure isolation chamber for patients with contagious diseases. Schematic of a network of rooms where air (shown in blue) flows in one direction from the corridor into the negative pressure room (green). Exhaust air is safely removed from the area through a ventilation system.

  5. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Room pressure can be either positive or negative with respect to outside the room. Positive pressure occurs when there is more air being supplied than exhausted, and is common to reduce the infiltration of outside contaminants. [23]

  6. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    It is worth noting that ACH measured with the blower door test, at a differential pressure of 50 pascals, mimics the situation of a sustained 20 mph (32 km/h) wind outside. The natural air leakage, under calmer conditions, is likely to be much less. As a result, the so-called natural ACH may be a factor of 10-25 times smaller. [14]

  7. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    An alternative approach to the multi-point procedure is to only measure fan airflow and building pressure differential at a single test point, such as 50 Pa, and then use an assumed pressure exponent, n Building in the analysis and generation of blower door metrics. This method is preferred by some for two main reasons: (1) measuring and ...

  8. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    Small pressure pan application. A third test method to determine if ductwork is leaking to the outside is to use a pressure pan, which is a register cover with a pressure tap for a hose connection. With the house pressurized (or depressurized) to 50 Pa (-50 Pa) using a blower door, a pressure gauge is attached to the pressure pan by means of a ...

  9. Passive ventilation - Wikipedia

    en.wikipedia.org/wiki/Passive_ventilation

    Above the neutral plane, the internal air pressure will be positive and air will flow out of any intermediate level apertures created. Below the neutral plane the internal air pressure will be negative and external air will be drawn into the space through any intermediate level apertures.

  1. Ad

    related to: positive pressure vs negative pressure hvac