Search results
Results From The WOW.Com Content Network
A diving regulator or underwater diving regulator is a pressure regulator that controls the pressure of breathing gas for underwater diving.The most commonly recognised application is to reduce pressurized breathing gas to ambient pressure and deliver it to the diver, but there are also other types of gas pressure regulator used for diving applications.
The first stage of the regulator is mounted to the cylinder valve or manifold via one of the standard connectors (Yoke or DIN). It reduces cylinder pressure to an intermediate pressure, usually about 8 to 11 bars (120 to 160 psi) higher than the ambient pressure, also called interstage pressure, medium pressure or low pressure. The breathing ...
Mixing by continuous blending: regulateed flow of oxygen is fed into a static mixer with air, analysed, and fed to the compressor inlet. The compressor and particularly the compressor oil, must be suitable for this service. If the oxygen fraction is less than 40%, some countries do not require the cylinder and valve to be cleaned for oxygen ...
The term "oxygen tank" is commonly used by non-divers; however, this is a misnomer since these cylinders typically contain (compressed atmospheric) breathing air, or an oxygen-enriched air mix. They rarely contain pure oxygen, except when used for rebreather diving, shallow decompression stops in technical diving or for in-water oxygen ...
An oxygen tank is especially dangerous because the gas is stored at a pressure of 21 MPa (3,000 psi; 210 atm)) when full. If the tank falls over and damages the valve, the tank can be jettisoned by the compressed oxygen escaping the cylinder at high speed. Tanks in this state are capable of breaking through a brick wall. [19]
Lowering the oxygen content of a breathing gas mixture increases the maximum operating depth and duration of the dive before which oxygen toxicity becomes a limiting factor. Most trimix divers limit their working oxygen partial pressure [PO 2 ] to 1.4 bar and may reduce the P O 2 further to 1.3 bar or 1.2 bar depending on the depth, the ...
For example, the US standard DOT 3AA requires the use of open-hearth, basic oxygen, or electric steel of uniform quality. Approved alloys include 4130X, NE-8630, 9115, 9125, Carbon-boron and Intermediate manganese, with specified constituents, including manganese and carbon, and molybdenum, chromium, boron, nickel or zirconium. [20]
Medical use liquid oxygen airgas tanks are typically 2.4 MPa (350 psi). [citation needed] All equipment coming into contact with high pressure oxygen must be "oxygen clean" and "oxygen compatible", to reduce the risk of fire. [3] [4] "Oxygen clean" means the removal of any substance that could act as a source of ignition. "Oxygen compatible ...