Search results
Results From The WOW.Com Content Network
Prior to 1990, the ICRP used the term "dose equivalent" to refer to the absorbed dose at a point multiplied by the quality factor at that point, where the quality factor was a function of linear energy transfer (LET). Currently, the ICRP's definition of "equivalent dose" represents an average dose over an organ or tissue, and radiation ...
Absorbed dose is a dose quantity which is the measure of the energy deposited in matter by ionizing radiation per unit mass. Absorbed dose is used in the calculation of dose uptake in living tissue in both radiation protection (reduction of harmful effects), and radiology (potential beneficial effects, for example in cancer treatment).
The Röntgen equivalent physical (rep), introduced by Herbert Parker in 1945, [12] was the absorbed energetic dose to tissue before factoring in relative biological effectiveness. The rep has variously been defined as 83 or 93 ergs per gram of tissue (8.3/9.3 mGy ) [ 13 ] or per cc of tissue.
The International Committee for Weights and Measures states: "In order to avoid any risk of confusion between the absorbed dose D and the dose equivalent H, the special names for the respective units should be used, that is, the name gray should be used instead of joules per kilogram for the unit of absorbed dose D and the name sievert instead ...
The absorbed dose required to produce a certain biological effect varies between different types of radiation, such as photons, neutrons or alpha particles. This is taken into account by the equivalent dose (H), which is defined as the mean dose to organ T by radiation type R (D T,R), multiplied by a weighting factor W R.
A model of deterministic risk would require different weighting factors (not yet established) than are used in the calculation of equivalent and effective dose. To avoid confusion, deterministic effects are normally compared to absorbed dose in units of rad, not rem. [9]
The CIPM also says that "in order to avoid any risk of confusion between the absorbed dose D and the dose equivalent H, the special names for the respective units should be used, that is, the name gray should be used instead of joules per kilogram for the unit of absorbed dose D and the name sievert instead of joules per kilogram for the unit ...
Equivalent dose and effective dose are measured in sieverts (Sv). [4] Dose quantities used in radiation protection. For example, suppose a person's small intestine and stomach are both exposed to radiation separately. [2] The absorbed dose of small intestine is 100 mSv and the absorbed dose of stomach is 70 mSv.