The time interval between the instant pick-up value and the closing contacts of the relay is very low. It has low operating time and starts operating instantly when the value of current is more than the relay setting. This relay operates only when the impedance between the source and the relay is less than that provided in the section. [33]
If the relay setting is determined to be below the apparent impedance it is determined that the fault is within the zone of protection. When the transmission line length is too short, less than 10 miles, distance protection becomes more difficult to coordinate. In these instances the best choice of protection is current differential protection.
Digital/numerical relays provide a front panel display, or display on a terminal through a communication interface. This is used to display relay settings and real-time current/voltage values, etc. More complex digital relays will have metering and communication protocol ports, allowing the relay to become an element in a SCADA system.
21 - Distance Relay; 21G - Ground Distance; 21P - Phase Distance; 22 – Equalizer Circuit Breaker; 23 – Temperature control device, Heater; 24 – Volts per Hertz Relay (in some old analog applications, a 59 and an 81 device would be chained together as a 59/81 to implement the equivalent of V/Hz protection) 25 – Synchronizing or ...
A relay allows circuits to be switched by electrical equipment: for example, a timer circuit with a relay could switch power at a preset time. For many years relays were the standard method of controlling industrial electronic systems. A number of relays could be used together to carry out complex functions (relay logic). The principle of relay ...
The distance to the reflecting impedance can also be determined from the time that a pulse takes to return. The limitation of this method is the minimum system rise time. The total rise time consists of the combined rise time of the driving pulse and that of the oscilloscope or sampler that monitors the reflections.
For example, in an induction type electromechanical relay, the time delay for the switching action can be adjusted by adjusting the distance traveled by the disc, whereas in a static relay the delay can be set by adjusting the value of the resistance in an R-C time delay circuit. Static relays may be based on analog solid state circuits ...
Another advantage is that more than one open-collector output can be connected to a single line. If all open collector outputs attached to a line are off (i.e. in the high-impedance state), the pull-up resistor will be the only device setting the line's voltage and will pull the line voltage high.