When.com Web Search

  1. Ads

    related to: pressure relief valve sizing calculator for water

Search results

  1. Results From The WOW.Com Content Network
  2. Restrictive flow orifice - Wikipedia

    en.wikipedia.org/wiki/Restrictive_flow_orifice

    It may be used to limit the accidental release of a hazardous gas (flammable, toxic, etc.) resulting from regulator or other component failure, restricting flow in a system in order to assure adequate pressure relief valve sizing and system over pressure protection, or restricting flow from bulk sources such as a water main. [3]

  3. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s, e.g. water. [clarify]

  4. Relief valve - Wikipedia

    en.wikipedia.org/wiki/Relief_valve

    A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.

  5. Safety valve - Wikipedia

    en.wikipedia.org/wiki/Safety_valve

    An oxygen safety relief valve DN250-safety valves. A safety valve is a valve that acts as a fail-safe.An example of safety valve is a pressure relief valve (PRV), which automatically releases a substance from a boiler, pressure vessel, or other system, when the pressure or temperature exceeds preset limits.

  6. Maximum allowable operating pressure - Wikipedia

    en.wikipedia.org/wiki/Maximum_allowable...

    Relief valves are set at the design pressure of the pressurized item and sized to prevent the item under pressure from being over-pressurized. Depending on the design code that the pressurized item is designed, an over-pressure allowance can be used when sizing the relief valve.

  7. Water hammer - Wikipedia

    en.wikipedia.org/wiki/Water_hammer

    The following characteristics may reduce or eliminate water hammer: Reduce the pressure of the water supply to the building by fitting a regulator. Lower fluid velocities. To keep water hammer low, pipe-sizing charts for some applications recommend flow velocity at or below 1.5 m/s (4.9 ft/s). Fit slowly closing valves.