Search results
Results From The WOW.Com Content Network
The principle is explained for a modern upright compound microscope, where the light source illuminates the specimen from below. The light passes the object of interest laterally upwards. When using the Lieberkühn reflector, the opening in the microscope stage is covered with a flat glass plate upon which the specimen is placed.
The Houghton telescope or Lurie–Houghton telescope is a design that uses a wide compound positive-negative lens over the entire front aperture to correct spherical aberration of the main mirror. If desired, the two corrector elements can be made with the same type of glass, since the Houghton corrector's chromatic aberration is minimal.
Köhler illumination is a method of specimen illumination used for transmitted and reflected light (trans- and epi-illuminated) optical microscopy.Köhler illumination acts to generate an even illumination of the sample and ensures that an image of the illumination source (for example a halogen lamp filament) is not visible in the resulting image.
The figure shows the optical path of a Mirau-interferometer. Reference beam (5-4-6) and object beam (5-7-6) have identical optical path length and can thus cause white light interference. Parts of the Mirau interferometer: 1. Lens of the microscope, 2. Semitransparent mirror, 3. Object surface, 4. Reference mirror with reference beam, 5.
The optical microscope, also referred to as a light microscope, is a type of microscope that commonly uses visible light and a system of lenses to generate magnified images of small objects. Optical microscopes are the oldest design of microscope and were possibly invented in their present compound form in the 17th century.
A condenser between the stage and mirror of a vintage microscope. Condensers are located above the light source and under the sample in an upright microscope, and above the stage and below the light source in an inverted microscope. They act to gather light from the microscope's light source and concentrate it into a cone of light that ...
Two Leica oil immersion microscope objective lenses; left 100×, right 40×. The objective lens of a microscope is the one at the bottom near the sample. At its simplest, it is a very high-powered magnifying glass, with very short focal length. This is brought very close to the specimen being examined so that the light from the specimen comes ...
It is named after Paul Kirkpatrick and Albert Baez, the inventors of the X-ray microscope. [1] Although X-rays can be focused by compound refractive lenses, these also reduce the intensity of the beam and are therefore undesirable. KB mirrors, on the other hand, can focus beams to small spot sizes with minimal loss of intensity.