When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    This does not include the uninsulated ground wire. For instance, if the cable lists "12-2 AWG", it means there are two insulated 12-gauge wires (a black and a white wire), plus a ground wire. If the label says "12-3", this cable has four conductors—three 12-gauge insulated wires and a bare copper ground wire. [5]

  3. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    When the cross-sectional area of a wire is doubled, the AWG will decrease by 3. (E.g. two 14 AWG wires have about the same cross-sectional area as a single 11 AWG wire.) This doubles the conductance. When the diameter of a solid round wire is doubled, the AWG will decrease by 6. (E.g. 1 mm diameter wire is ≈18 AWG, 2 mm diameter wire is ≈12 ...

  4. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    A wire or cable has a voltage (to neutral) rating and a maximum conductor surface temperature rating. The amount of current a cable or wire can safely carry depends on the installation conditions. The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission.

  5. Tri-rated cable - Wikipedia

    en.wikipedia.org/wiki/Tri-rated_cable

    Wire that is approved to BS 6231 might not carry the UL and CSA ratings, if, for example, the wire is not suitable for use at the higher 105 °C temperature that is specified for those ratings. In that case, the wire is not tri-rated. According to UL 758, the maximum operating temperature of tri-rated cable is 105 °C. British Standard BS 6231 ...

  6. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    Also, the size of the aluminum wire needs to be larger compared to copper wire used for the same circuit due to the increased resistance of the aluminum alloys. For example, a 15 A branch circuit supplying standard lighting fixtures can be installed with either #14 AWG copper building wire or #12 AWG aluminum building wire according to the NEC ...

  7. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  8. Electrical cable - Wikipedia

    en.wikipedia.org/wiki/Electrical_cable

    Coaxial cable – used for radio frequency signals, for example in cable television distribution systems. Direct-buried cable; Flexible cables; Filled cable; Heliax cable; Non-metallic sheathed cable (or nonmetallic building wire, NM, NM-B) [6] Armored cable (or BX) [6] Multicore cable (consist of more than one wire and is covered by cable jacket)

  9. Arcadia (engineering) - Wikipedia

    en.wikipedia.org/wiki/Arcadia_(engineering)

    ARCADIA, a model-based engineering method for systems, hardware and software architectural design. ARCADIA ( Arc hitecture A nalysis & D esign I ntegrated A pproach) is a system and software architecture engineering method based on architecture-centric and model-driven engineering activities.