When.com Web Search

  1. Ad

    related to: back pressure vs back siphonage standard rate

Search results

  1. Results From The WOW.Com Content Network
  2. Backflow - Wikipedia

    en.wikipedia.org/wiki/Backflow

    Backflow occurs for one of two reasons, either back pressure or back siphonage. [1] Back pressure is the result of a higher pressure in the system than in its supply, i.e. the system pressure has been increased by some means. This may occur in unvented heating systems, where thermal expansion increases the pressure. Back siphonage is the result ...

  3. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Back-siphonage occurs when higher pressure fluids, gases, or suspended solids move to an area of lower pressure fluids. For example, when a drinking straw is used to consume a beverage, suction reduces the pressure of fluid inside the straw, causing liquid to move from the cup to inside the straw and then into the drinker's mouth.

  4. Back pressure - Wikipedia

    en.wikipedia.org/wiki/Back_pressure

    Back pressure is the term used for the hydraulic pressure required to create a flow through a chromatography column in high-performance liquid chromatography, the term deriving from the fact that it is generated by the resistance of the column, and exerts its influence backwards on the pump that must supply the flow.

  5. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    In the case of the downstream check valve passing, the differential pressure relief valve prevents the possibility of the chamber pressure from exceeding the supply pressure. It is theoretically possible that, when both valves are faulty, backflow could occur, should the reverse flow rate exceed the capacity of the relief valve.

  6. Siphon - Wikipedia

    en.wikipedia.org/wiki/Siphon

    For water at standard atmospheric pressure, the maximal siphon height is approximately 10 m (33 feet); for mercury it is 76 cm (30 inches), which is the definition of standard pressure. This equals the maximal height of a suction pump , which operates by the same principle.

  7. Double check valve - Wikipedia

    en.wikipedia.org/wiki/Double_check_valve

    The double check valve assembly is suitable for prevention of back pressure and back siphonage, but is not suitable for high hazard applications. It is commonly used on lawn irrigation , fire sprinkler [ 2 ] and combi-boiler systems. [ 3 ]

  8. Choked flow - Wikipedia

    en.wikipedia.org/wiki/Choked_flow

    This is referred as overexpanded flow because in this case the pressure at the nozzle exit is lower than that in the ambient (the back pressure)- i.e. the flow has been expanded by the nozzle too much. [13] A further lowering of the back pressure changes and weakens the wave pattern in the jet.

  9. Compressor characteristic - Wikipedia

    en.wikipedia.org/wiki/Compressor_characteristic

    Compressor characteristic is a mathematical curve that shows the behaviour of a fluid going through a dynamic compressor.It shows changes in fluid pressure, temperature, entropy, flow rate etc.) with the compressor operating at different speeds.