When.com Web Search

  1. Ad

    related to: ventricular paced rhythm

Search results

  1. Results From The WOW.Com Content Network
  2. Accelerated idioventricular rhythm - Wikipedia

    en.wikipedia.org/wiki/Accelerated_idio...

    Accelerated idioventricular rhythm is a ventricular rhythm with a rate of between 40 and 120 beats per minute. Idioventricular means “relating to or affecting the cardiac ventricle alone” and refers to any ectopic ventricular arrhythmia. [ 1 ]

  3. Sgarbossa's criteria - Wikipedia

    en.wikipedia.org/wiki/Sgarbossa's_criteria

    Sgarbossa's criteria are a set of electrocardiographic findings generally used to identify myocardial infarction (also called acute myocardial infarction or a "heart attack") in the presence of a left bundle branch block (LBBB) or a ventricular paced rhythm. [1] Myocardial infarction (MI) is often difficult to detect when LBBB is present on ECG ...

  4. Ventricular escape beat - Wikipedia

    en.wikipedia.org/wiki/Ventricular_escape_beat

    Ventricular pacemaker cells discharge at a slower rate than the SA or AV node. While the SA node typically initiates a rate of 70 beats per minute (BPM), the atrioventricular node (AV node) is usually only capable of generating a rhythm at 40-60 BPM or less. Ventricular contraction rate is thus reduced by 15-40 beats per minute. [3]

  5. Arrhythmia - Wikipedia

    en.wikipedia.org/wiki/Arrhythmia

    Groups of three premature ventricular beats are called triplets and are considered a brief run of non-sustained ventricular tachycardia (NSVT); if the grouping lasts for more than 30 seconds, it is considered sustained ventricular tachycardia (VT). [14] Accelerated idioventricular rhythm; Monomorphic ventricular tachycardia

  6. Idioventricular rhythm - Wikipedia

    en.wikipedia.org/wiki/Idioventricular_rhythm

    An idioventricular rhythm is a cardiac rhythm characterized by a rate of <50 beats per minute (bpm), absence of conducted P waves and widening of the QRS complex. [1] In cases where the heart rate is between 50 and 110 bpm, it is known as accelerated idioventricular rhythm and ventricular tachycardia if the rate exceeds 120 bpm.

  7. Ectopic pacemaker - Wikipedia

    en.wikipedia.org/wiki/Ectopic_pacemaker

    An ectopic pacemaker located in the atria is known as an atrial pacemaker and can cause the atrial contraction to be faster. [10] An ectopic pacemaker situated near the AV node and the septum is known as a junctional pacemaker. [11] The pacemaker that is operating in the ventricles is known as the ventricular. [12]

  8. Fusion beat - Wikipedia

    en.wikipedia.org/wiki/Fusion_beat

    Ventricular fusion beats can occur when the heart's natural rhythm and the impulse from a pacemaker coincide to activate the same part of a ventricle at the same time, causing visible variation in configuration and height of the QRS complex of an electrocardiogram reading of the heart's activity. [2]

  9. Rhythm interpretation - Wikipedia

    en.wikipedia.org/wiki/Rhythm_interpretation

    There are 6 different sinus arrhythmia. [1] [2]A normal heart should have a normal sinus rhythm, this rhythm can be identified by a ventricular rate of 60-100 bpm, at a regular rate, with a normal PR interval (0.12 to 0.20 second) and a normal QRS complex (0.12 second and less).