Accelerated idioventricular rhythm is a ventricular rhythm with a rate of between 40 and 120 beats per minute. Idioventricular means “relating to or affecting the cardiac ventricle alone” and refers to any ectopic ventricular arrhythmia. [ 1 ]
Sgarbossa's criteria are a set of electrocardiographic findings generally used to identify myocardial infarction (also called acute myocardial infarction or a "heart attack") in the presence of a left bundle branch block (LBBB) or a ventricular paced rhythm. [1] Myocardial infarction (MI) is often difficult to detect when LBBB is present on ECG ...
Ventricular pacemaker cells discharge at a slower rate than the SA or AV node. While the SA node typically initiates a rate of 70 beats per minute (BPM), the atrioventricular node (AV node) is usually only capable of generating a rhythm at 40-60 BPM or less. Ventricular contraction rate is thus reduced by 15-40 beats per minute. [3]
Groups of three premature ventricular beats are called triplets and are considered a brief run of non-sustained ventricular tachycardia (NSVT); if the grouping lasts for more than 30 seconds, it is considered sustained ventricular tachycardia (VT). [14] Accelerated idioventricular rhythm; Monomorphic ventricular tachycardia
An idioventricular rhythm is a cardiac rhythm characterized by a rate of <50 beats per minute (bpm), absence of conducted P waves and widening of the QRS complex. [1] In cases where the heart rate is between 50 and 110 bpm, it is known as accelerated idioventricular rhythm and ventricular tachycardia if the rate exceeds 120 bpm.
An ectopic pacemaker located in the atria is known as an atrial pacemaker and can cause the atrial contraction to be faster. [10] An ectopic pacemaker situated near the AV node and the septum is known as a junctional pacemaker. [11] The pacemaker that is operating in the ventricles is known as the ventricular. [12]
Ventricular fusion beats can occur when the heart's natural rhythm and the impulse from a pacemaker coincide to activate the same part of a ventricle at the same time, causing visible variation in configuration and height of the QRS complex of an electrocardiogram reading of the heart's activity. [2]
There are 6 different sinus arrhythmia. [1] [2]A normal heart should have a normal sinus rhythm, this rhythm can be identified by a ventricular rate of 60-100 bpm, at a regular rate, with a normal PR interval (0.12 to 0.20 second) and a normal QRS complex (0.12 second and less).