When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Transient recovery voltage - Wikipedia

    en.wikipedia.org/wiki/Transient_Recovery_Voltage

    A terminal fault is a fault that occurs at the circuit breaker terminals. The circuit breaker interrupts a short-circuit at current zero, at this instant the supply voltage is maximum and the recovery voltage tends to reach the supply voltage with a high frequency transient. The normalized value of the overshoot or amplitude factor is 1.4.

  3. Clamper (electronics) - Wikipedia

    en.wikipedia.org/wiki/Clamper_(electronics)

    The negative swing of the output will not dip below about −0.6 V, assuming a silicon PN diode. [1] A clamper (or clamping circuit or clamp) is an electronic circuit that fixes either the positive or the negative peak excursions of a signal to a defined voltage by adding a variable positive or negative DC voltage to it. [2]

  4. English: What it does is use diode clamps to eliminate over and undershoot. The "trick" is that instead of clamping to +5 and GND they clamp to the output of two regulated voltages. This allows the clamping diodes to turn on earlier and is therefore better at eliminating overshoot and undershoot.

  5. Transient response - Wikipedia

    en.wikipedia.org/wiki/Transient_response

    In electrical engineering specifically, the transient response is the circuit’s temporary response that will die out with time. [1] It is followed by the steady state response, which is the behavior of the circuit a long time after an external excitation is applied.

  6. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    On a 3-phase circuit, a recloser is more beneficial than three separate fuse cutouts. For example, on a wye to delta conversion, when cutouts are used on the wye side and only 1 out of 3 of the cutout fuses open, some customers on the delta side have a low voltage condition, due to voltage transfer through the transformer windings. Low voltage ...

  7. Snubber - Wikipedia

    en.wikipedia.org/wiki/Snubber

    The diode must immediately enter into forward conduction mode as the driving current is interrupted. Most ordinary diodes, even "slow" power silicon diodes, are able to turn on very quickly, [3] in contrast to their slow reverse recovery time. These are sufficient for snubbing electromechanical devices such as relays and motors.

  8. Circuit breaker (overcurrent) - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker_(overcurrent)

    High-voltage circuit breakers used on transmission systems may be arranged to allow a single pole of a three-phase line to trip, instead of tripping all three poles; for some classes of faults this improves the system stability and availability. High-voltage direct current circuit breakers are still a field of research as of 2015. Such breakers ...

  9. Vacuum interrupter - Wikipedia

    en.wikipedia.org/wiki/Vacuum_interrupter

    In 1956, Hugh C. Ross at Jennings Radio Manufacturing Corporation revolutionized the high-frequency-circuit vacuum switch and produced a vacuum switch with a rating of 15 kV at 200 A. Five years later, Thomas H. Lee at General Electric produced the first vacuum circuit breakers [2] [3] with a rated voltage of 15 kV at short-circuit breaking ...