  2. Template:Table of MRI sequences - Wikipedia

    en.wikipedia.org/wiki/Template:Table_of_MRI...

    Dynamic susceptibility contrast: DSC: Measures changes over time in susceptibility-induced signal loss due to gadolinium contrast injection. [20] Provides measurements of blood flow; In cerebral infarction, the infarcted core and the penumbra have decreased perfusion and delayed contrast arrival (pictured). [21] Arterial spin labelling: ASL

  3. Susceptibility weighted imaging - Wikipedia

    en.wikipedia.org/wiki/Susceptibility_weighted...

    Susceptibility weighted imaging (SWI), originally called BOLD venographic imaging, is an MRI sequence that is exquisitely sensitive to venous blood, hemorrhage and iron storage. SWI uses a fully flow compensated, long echo, gradient recalled echo (GRE) pulse sequence to acquire images.

  4. Quantitative susceptibility mapping - Wikipedia

    en.wikipedia.org/wiki/Quantitative...

    COSMOS assumes a model-free susceptibility distribution and keeps full fidelity to the measured data. This method has been validated extensively in in vitro, ex vivo and phantom experiments. Quantitative susceptibility maps obtained from in vivo human brain imaging also showed high degree of agreement with previous knowledge about brain anatomy ...

  5. Magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Magnetic_resonance_imaging

    Magnetic resonance imaging (MRI) is a medical imaging technique used in radiology to generate pictures of the anatomy and the physiological processes inside the body. MRI scanners use strong magnetic fields , magnetic field gradients, and radio waves to form images of the organs in the body.

  6. MRI pulse sequence - Wikipedia

    en.wikipedia.org/wiki/MRI_pulse_sequence

    Susceptibility-weighted imaging (SWI) is a new type of contrast in MRI different from spin density, T 1, or T 2 imaging. This method exploits the susceptibility differences between tissues and uses a fully velocity-compensated, three-dimensional, RF-spoiled, high-resolution, 3D-gradient echo scan.

  7. k-space in magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/K-space_in_magnetic...

    However, these techniques are approximate due to phase errors in the MRI data which can rarely be completely controlled (due to imperfect static field shim, effects of spatially selective excitation, signal detection coil properties, motion etc.) or nonzero phase due to just physical reasons (such as the different chemical shift of fat and ...

  8. Phase contrast magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Phase_Contrast_Magnetic...

    Phase contrast MRI is one of the main techniques for magnetic resonance angiography (MRA). This is used to generate images of arteries (and less commonly veins) in order to evaluate them for stenosis (abnormal narrowing), occlusions , aneurysms (vessel wall dilatations, at risk of rupture) or other abnormalities.

  9. HARP (algorithm) - Wikipedia

    en.wikipedia.org/wiki/HARP_(algorithm)

    Harmonic phase (HARP) algorithm [1] is a medical image analysis technique capable of extracting and processing motion information from tagged magnetic resonance image (MRI) sequences. It was initially developed by N. F. Osman and J. L. Prince at the Image Analysis and Communications Laboratory at Johns Hopkins University. The method uses ...